EP-MA73, EP-MA73KU892 (serv.man2) - Panasonic Other Service Manuals Service Manual (repair manual). Page 21

Read Panasonic EP-MA73 / EP-MA73KU892 (serv.man2) Service Manual online

21
C8
Display of Sensor faulty
Display of the sensor condition in which 
abnormal stop occurred
00: OK
01: Up/down sensor no change
02: Up/down sensor abnormal change
03: Abnormal when Up/down motor 
starts
04: Width sensor no change
05: Width sensor abnormal change
06: Abnormal when Width motor starts
07: Intensity sensor no change
08: Intensity sensor abnormal change
09: Abnormal when Intensity motor 
starts
10: Tapping motor rotation faulty
11: Ottoman sensor no change
12: Ottoman sensor abnormal change
13: Reclining sensor no change
14: Reclining sensor abnormal change
15: Massage block heater error
16: Foot heater error
C9
01 Display of abnormal stop condition Display of the Controller condition when abnormal stop occurred
02 Display of accumulative abnormal 
stop conditions
Display of accumulative abnormal stop conditions
03 Delete of the display of accumula-
tive abnormal stop conditions
Delete of the display of accumulative abnormal stop conditions
CA
Checking after assembly
Checking each operations
CC
Adjustment of Pressure sensor
Deciding the standard of the Massage sensor
CE
Moving Massage mechanism block 
freely
Moving Massage mechanism block manually
00
Packing
Backrest reclines and Massage mechanism block moves to the storage position
Entry
Operation mode
Explanation of the summary
Display
Type
No.
Page of 88
Display

Click on the first or last page to see other EP-MA73 / EP-MA73KU892 (serv.man2) service manuals if exist.