VDR-M30PP, VDR-M30EG, VDR-M30B, VDR-M30EN - Panasonic Movie Service Manual Supplement (repair manual). Page 47

Read Panasonic VDR-M30PP / VDR-M30EG / VDR-M30B / VDR-M30EN Service Manual Supplement online

  7) Connect the oscilloscope CH1 to “EVF-B (pin 6)” of
Skylark Connection jig.
  8) Use the same procedure as in step 3) to equalize levels a
and b of the waveform. (See Fig. 6-4-16)
  9) After step 8) is complete, be sure to click the NEXT
button, and then proceed with the SUB CONTRAST
BLUE ADJUSTMENT screen.
10) Use the same procedure as in step 3) to equalize levels c
and d of the waveform.
11) After step 10) is complete, be sure to click the SAVE
button and then proceed with the BL DET screen.
Note that clicking the RETURN button will restore the
EVF ADJUSTMENT MENU screen to the status before
the adjustment was performed.
12) Click either button on the BL DET screen according to
the voltage checked in “(1) BL DET Check”: “High”
button when the check value is 5 V, or  “Low” button
when it is 0 V.
13) When BL DET is complete, the ADJUSTMENT
FINISHED dialog will appear: Click the OK button in
dialog to restore the EVF ADJUSTMENT MENU
screen.
14) Click the RETURN button in EVF ADJUSTMENT
MENU to restore the ADJUST MENU screen.
SUB BRIGHT BLUE ADJUSTMENT
screen.
SUB CONTRAST BLUE ADJUSTMENT
screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
NEXT
RETURN
SUB BRIGHT BLUE ADJUSTMENT
UP
DOWN
9
8
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
SAVE
RETURN
SUB CONTRAST BLUE ADJUSTMENT
UP
DOWN
11
10
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
BL DET
High
Low
12
BL DET screen.
ADJUSTMENT FINISHED dialog
FINISHED
ADJUSTMENT FINISHED.
OK
13
FINISHED
ADJUSTMENT FINISHED.
OK
13
47
VDR-M30PP / VDR-M30EG / VDR-M30B / VDR-M30EN
Page of 47
Display

Download Panasonic VDR-M30PP / VDR-M30EG / VDR-M30B / VDR-M30EN Service Manual Supplement