Read Panasonic HDC-TM10PP / HDC-TM10PU / HDC-TM10EB / HDC-TM10EC / HDC-TM10EE / HDC-TM10EF / HDC-TM10EP / HDC-TM10GC / HDC-TM10GK / HDC-TM10GN / HDC-SD10PP / HDC-SD10PU / HDC-SD10EB / HDC-SD10EC / HDC-SD10EE / HDC-SD10EF / HDC-SD10EG / HDC-SD10EP / HDC-SD10GC / HDC-SD10 Service Manual online
HDC-TM10PU
HDC-TM10EB
HDC-TM10EC
HDC-TM10EE
HDC-TM10EF
HDC-TM10EP
HDC-TM10GC
HDC-TM10GK
HDC-TM10GN
HDC-SD10PP
HDC-SD10PU
HDC-SD10EB
HDC-SD10EC
HDC-SD10EE
HDC-SD10EF
HDC-SD10EG
HDC-SD10EP
HDC-SD10GC
HDC-SD10GK
(S)...........Silver Type
(R)...........Red Type
HDC-SD10EB/EC/GC/GK)
1.2. Leakage Current Cold Check ---------------------------3
1.3. Leakage Current Hot Check (See Figure 1.) --------3
1.4. How to Discharge the Capacitor on Sub
2.4. How to Replace the Lithium Battery -------------------7
3.2. General Description About Lead Free Solder
3.4. How to Define the Model Suffix (NTSC or PAL
5 Location of Controls and Components------------------ 13
6 Service Mode ----------------------------------------------------- 17
6.2. Lock Search History Indication ----------------------- 19
6.3. Power ON Self Check Result Display--------------- 20
7.2. Service Position ------------------------------------------ 21
8.2. P.C.B. Location ------------------------------------------- 22
8.3. Disassembly Procedure -------------------------------- 23
10.2. What Is The Factory Settings? ----------------------- 40
which are important for safety. These parts are marked by
tial that these critical parts should be replaced with manu-
facturer’s specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
from the AC power line. Use a transformer of adequate
power rating as this protects the technician from acci-
dents resulting in personal injury from electrical shocks. It
will also protect AC Adaptor from being damaged by acci-
dental shorting that may occur during servicing.
heated or damaged by the short circuit.
properly installed.
shock hazards.
lic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metal-
lic part has a return path to the chassis, the reading
should be between 1 M
reading must be infinity.
(See Figure 1.)
and a good earth ground, as shown in Figure 1.
lent) may be used to make the hot checks, leakage cur-
rent must not exceed 1/2 mA. In case a measurement is
outside of the limits specified, there is a possibility of a
shock hazard, and the equipment should be repaired and
rechecked before it is returned to the customer.
2. Be careful of the high voltage circuit on SUB P.C.B. when servicing.
2. Put the insulation tube onto the lead part of Resistor (ERG5SJ102:1k
4. After discharging confirm that the capacitor voltage is lower than 10V using a voltmeter.