SD-ZB2512KTS - Panasonic Home Appliance Service Manual (repair manual). Page 25

Read Panasonic SD-ZB2512KTS Service Manual online

25
5.3.4.
Heater operation test mode
Operation procedure
1. Press the "
"  key.
Phenomena
• LCD indication: It light up like the next figure.
• Behaviour of device: The device supplies electric power to
the heater after 1 second and the power is off when the sen-
sor temperature reaches 165 deg.C.
• Restoration: Pressing "
" key, the device returns to the
main body initial test mode.
Judgement/Remedy
• Replace the sensor and/or P.C.Board B if the power is not off
when the sensor temperature reaches 165 deg.C.
• Replace the heater and/or P.C.Board B if the heater does
not work normally.
• Replace P.C.Board A if the device does not work normally
after trying the above remedy.
5.3.5.
Sensor inspection mode
Operation procedure
1. Press the "
" key.
Phenomena
• LCD indication: It light up like the next figure.
• Behaviour of device: The device supplies electric power to
the heater for 3 seconds at an interval of 32 seconds and
controls the sensor temperature at approx. 35 deg.C.
• Restoration: Pressing "
" key, the device returns to the
main body initial test mode.
Judgement
• The P.C.Boards and heater work properly when the temper-
ature inside the unit is controlled at approx. 35 deg.C.
Page of 49
Display

Click on the first or last page to see other SD-ZB2512KTS service manuals if exist.