Read Panasonic NT-T13P (serv.man3) Service Manual online
3.2 Points to check after assembly
After assembly, carry out the following tests.
Insulation resistance/Shall be 2 M© or more when measured with a 500V DC insulation-resistance
tester./Measuring point: Between the two blades of the plug and bottom plate
tester./Measuring point: Between the two blades of the plug and bottom plate
1.
Dielectric strength:/Shall withstand 1000V AC for one minute:/Measuring point: same point as the
insulation test
insulation test
2.
Grounding resistance/Shall not exceed 0.08©./Measuring point: Between the grounding terminal
and bottom plate
and bottom plate
3.
Quick performance test/Perform the "Quick performance test" described in section 3.1 to make
sure that the product functions well.
sure that the product functions well.
4.
file:///C|/Ìîè äîêóìåíòû/NT_T13/s0302000000.html [10.01.2002 10:37:45]