Read Panasonic NR-D513XB-S8 / NR-D513XR-S8 Service Manual online
2.5 WAITING CONTROL FOR COMPRESSOR RE-STARTING
2.6 FAN MOTOR CONTROL FOR QUICK DEODORIZER
2.7 FAN MOTOR CONTROL IN FREEZER COMPARTMENT
2.8 PROTECTION OF INVERTER CIRCUIT
CODE
"MAX"LED: light off
H41
"MED"LED: light on
"MIN"LED: light on
"QUICK DEODORIZER "LED: light off
"QUICK FREEZING" LED: light on
2.9 DOOR ALARM
after 3 minutes
Operation PCB Display
DOOR OPENING
Buzzer sounds
after 5 minutes
Pee,Pee,Pee,Pee
Pee,Pee,Pee,…….
Waiting time for compressor starting
10 minutes
3 minutes
After compressor stops
After defrosting
after 1 minute
Pee,Pee
To re-start the compressor smoothly after compressor stops and after defrosting, it does not actuate the compressor
for certain period.
for certain period.
Caution
At once unplug, wait for 10 minutes, then plug in.
At once unplug, wait for 10 minutes, then plug in.
*When the green light is blinking after pressing the "QUICK DEODORIZER" button, the function of quick deodoring is
waiting .The situation of refrigerator is processing as below:
a.The refrigerator is defrosting .
b.The compressor is stopped,because temperature of the freezing compartment reachs setting of temperature.
c.The door of refrigerator compartment is opened.
When the above situation is solved , quick deodorization will be started automatically ,then the "QUICK
DEODORIZER"
light bright is on.
*Quick deodoring automatically ends ,then the green light is off. (Approx. 2~ 3 minutes)
waiting .The situation of refrigerator is processing as below:
a.The refrigerator is defrosting .
b.The compressor is stopped,because temperature of the freezing compartment reachs setting of temperature.
c.The door of refrigerator compartment is opened.
When the above situation is solved , quick deodorization will be started automatically ,then the "QUICK
DEODORIZER"
light bright is on.
*Quick deodoring automatically ends ,then the green light is off. (Approx. 2~ 3 minutes)
The fan motor (near FC evaporator )is controlled under below condition.
compartment is closed.Rotation speed changes on 4 degree according to atmosphere temperature and
refrigerator compartment.
compartment is closed.Rotation speed changes on 4 degree according to atmosphere temperature and
refrigerator compartment.
When supply voltage drops, IPM protection operates, and compressor protection operates continuously,
compressor stops at the moment and indicates code"H41".
compressor stops at the moment and indicates code"H41".
When the door of refrigerator compartment is opened after 5 minute ,"QUICK FREEZING"light is red.
"QUICK FREEZING"light is off,when the door of refrigerator compartment is closed.
"QUICK FREEZING"light is off,when the door of refrigerator compartment is closed.