4.3 Symptom 2. FC/PC are poor cooling.
*Replace defrost sensor
(sensor of resistance is smaller)
(sensor of resistance is smaller)
*Replace control PCB.
(Faulty of defrost sensor of circuit
detected on control PCB)
(Faulty of defrost sensor of circuit
detected on control PCB)
Does evaporator get too much frost?
NO
Is resistance of defrost sensor
6.33-6.437kΩ(at 0 ℃)
6.33-6.437kΩ(at 0 ℃)
YES
NO
YES
*Re-put Defrost of sensor position.
( Defrost of sensor drop)
( Defrost of sensor drop)
-11-