Read Panasonic NN-GM342WZPE Service Manual online
5-11
COMPONENTS
TEST PROCEDURE
RESULTS
FAN MOTOR
(Wire leads removed)
(Wire leads removed)
TURNTABLE
MOTOR
(Wire leads removed)
MOTOR
(Wire leads removed)
Measure the resistance.
(Ohm-meter scale: R x 100)
(Ohm-meter scale: R x 100)
Measure the resistance.
(Ohm-meter scale: R x 1000)
(Ohm-meter scale: R x 1000)
Normal:
Abnormal:
∞ or several Ω
Normal: Approx.100~200 K
Abnormal:
Abnormal:
∞
00~500
1
NOTE : • A MICROWAVE LEAKAGE TEST MUST ALWAYS BE PERFORMED WHEN THE UNIT IS
SERVICED FOR ANY REASON.
• MAKE SURE THE WIRE LEADS ARE IN THE CORRECT POSITION.
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
• WHEN REMOVING THE WIRE LEADS FROM THE PARTS, BE SURE TO GRASP THE
CONNECTOR, NOT THE WIRES.
HEATER ELEMENT
(Wire leads removed.)
(Wire leads removed.)
Measure the resistance.
(Multi-meter scale: Rx1)
(Multi-meter scale: Rx1)
Measure the resistance with 500V-100M ohm
insulation resistance meter.
insulation resistance meter.
Normal:
*Grill heater
Approx. 54
(at 20 ~ 30°C)
*Grill heater
Approx. 54
(at 20 ~ 30°C)
Normal: more than 0.5 Meg
NOTE: Make sure heater is fully cooled when tested.
Ω
Ω
Ω
Ω
Click on the first or last page to see other NN-GM342WZPE service manuals if exist.