NN-GD588S, NN-GT548M, NN-GT548MZPE, NN-GD588SZPE - Panasonic Home Appliance Service Manual Simplified (repair manual). Page 13

Read Panasonic NN-GD588S / NN-GT548M / NN-GT548MZPE / NN-GD588SZPE Service Manual Simplified online

5.3. Troubleshooting of inverter circuit (U) and magnetron
This oven is programmed with a self diagnostics failure code system which will help for troubleshooting. H95, H97, H98 and H99
are the provided failure codes to indicate magnetron and inverter circuit problem areas. This section explains failure codes of H95,
H97, H98 and H99. First, you must program the DPC into TEST MODE, press Clock button once
→ press Timer button once
→ Press Start button once → press Micro Power button once. Program unit for operation. H95, H97, H98, H99 appears in
display window a short time after [Start] button is pressed and there is no microwave oscillation.
Alternate way to troubleshoot oven with AC Ampere meter used
H95, H97, H98, H99 appears in display window a short time after [Start] button is pressed and no microwave oscillation with AC
Ampere meter used for troubleshooting.
13
NN-GD588S / NN-GT548M
Page of 29
Display

Click on the first or last page to see other NN-GD588S / NN-GT548M / NN-GT548MZPE / NN-GD588SZPE service manuals if exist.