NN-DF383BZPE - Panasonic Home Appliance Service Manual (repair manual). Page 15

Read Panasonic NN-DF383BZPE Service Manual online

4.4. Low voltage transformer
and/or power relays
CAUTION:
Be sure to ground any static electric charge built up in
your body before handling the DPC.
 1. Using solder wick or a desoldering tool and 30W soldering
iron carefully remove all solder from the terminal pins of the
low voltage transformer and/or power relays.
NOTE:
Do not use a soldering iron or desoldering tool of
more than 30 watts on D.P.C. contacts.
 2. With all the terminal pins cleaned and separated from
D.P.C. contacts, remove the defective transformer/power
relays, Replace components making sure all terminal pins
are inserted completely resolder all terminal contacts
carefully.
4.5. Fan motor
 1. Disconnect 2 lead wires from fan motor terminals.
 2. Remove 2 screws holding fan motor and detach fan motor
from oven assy.
 3. Remove fan blade from fan motor shaft by pulling it straight
out.