NI-U755XR, NI-U555SR, NI-U455SS, NI-U355TS - Panasonic Home Appliance Service Manual (repair manual). Page 11

Read Panasonic NI-U755XR / NI-U555SR / NI-U455SS / NI-U355TS Service Manual online

TROUBLE SHOOTING GUIDE
CONDITION
CHECK POINT
CAUSE
REMEDY
No steam or poor
steaming force
A.  Check if Dial thermo is set
      at "       " .(red area on Dial
      thermo)
A-1.  Too low a temperature may
         cause poor discharge of steam
         or water dropping.
B.  Remove the Handle assembly,
     fill it with water and set the
     Steam/Dry selector in steam
     position while Handle assembly
     is held horizontally.
B-1.  If water does not drip con-
         stantly from the bottom
         opening, it may be clogged.
C.  Check temperature control
      range (TEMPERATURE TEST
      METHOD).
C-1.  Refer to Item A-1.
(Perform STEAM
 TEST  refer to
 Page 8.)
D.  Check for clogged steam
      vents on the Soleplate.
D-1.  Clogged steam vents may
         cause poor steaming.
G-1.  Improper care for the iron
        after each use and/or high
        mineral content water.
White powder like
particles come
out from steam
vents while stea-
ming
G . Check if white particles come
     out while steaming.
(Perform STEAM TEST
refer to Page8.)
H.  Check if the Spray mist button
      operates correctly.
I.   Check if there is any clogging
      of nozzle.
H-1.  The Spray mist button is
         defective.
I -1.  The Spray nozzle is clogged.
No spray mist
J.  Check if Jet-of-steam button
      operates correctly.
K.  Check if the Balls are put in.
L.  Temperature setting is too low.
J-1.  The Jet-of-steam button is
         defective.
K-1.  The Balls are not put in.
L-1.  Temperature setting is too
         low.
Replace the Jet-of-steam
button assembly.
Put in the Balls.
Adjust the temperature or
replace Soleplate.
Jet-of-steam is no
put out
Replace the Spray nozzle
assembly.
9
E.  Refer to item A.
F.   Refer to item C.
Water leaks from
steam vents
Follow the collect instru-
ctions for carrying and
storing the iron.
If Soleplate is damged it
will have to be replaced.
Set Dial thermo at  "        " .
Clean opening or replace
Handle assembly if
necessary.
Reset the adjusting screw
or refer to TEMPERATURE
TEST METHOD,Page 7.
Clean steam vents.
Clean the nozzle.
Page of 13