NC-EH22P, NC-EH30P, NC-EH40P, NC-EH30PWTW, NC-EH40PWTW - Panasonic Home Appliance Service Manual (repair manual). Page 10

Read Panasonic NC-EH22P / NC-EH30P / NC-EH40P / NC-EH30PWTW / NC-EH40PWTW Service Manual online

᷷ᐲࡅࡘ࡯࠭㧔ቢᚑ㧕ߣࠨ࡯ࡒࠬ࠲㧔ቢᚑ㧕
૞ᬺࡐࠗࡦ࠻
⚵┙ᤨߩࡐࠗࡦ࠻
ᵈญ࡮ࡠ࠶ࠢ࡟ࡃ࡯ #㧔߰ߚ⌕⣕ߟ߹ߺ㧕
⚵┙ᤨߩࡐࠗࡦ࠻
᷷ᐲࡅࡘ࡯࠭㧔ቢᚑ㧕ߣࠨ࡯ࡒࠬ࠲㧔ቢᚑ㧕
૞ᬺࡐࠗࡦ࠻
⚵┙ᤨߩࡐࠗࡦ࠻
ᵈญ࡮ࡠ࠶ࠢ࡟ࡃ࡯ #㧔߰ߚ⌕⣕ߟ߹ߺ㧕
⚵┙ᤨߩࡐࠗࡦ࠻
DISASSEMBLY-7
w Remove this 
portion in the 
manner indicated 
with the arrow.
DISASSEMBLY-8
- 10 -
NC-EH22P, EH30P, EH40P
  1. Remove the screws from the thermal insulator cover.
  2. Remove the orange, white and yellow wires from the 
heater terminals. 
  3. Remove the thermal insulator cover from the body.
  4. Remove the nonfl ammable tube B. 
  5. Remove the thermal fuse comp. from the thermal 
insulator cover. 
  6. Remove the holding spring A of the thermistor comp. 
from the thermal insulator cover. 
  7. Before removing the thermistor comp. from holding 
spring A, turn it 90 degrees.
Service point 
 
  Remove the orange, white, and red lead wires with 
long nose type pliers.
Point in reassembly 
 
  Do not mishandle the thermal fuse comp. such as 
pulling, bending or twisting. 
 
  In assembling thermistor comp., be careful of 
gradient. 
 
  In assembling thermistor comp., make sure to apply 
the lubricating agent A.
 
 
CAUTION
If the lubricating agent A is not applied 
during the thermistor assembly, sensitiv-
ity of thermistor becomes worse. 
When assembling the thermistor, make sure 
to apply the lubricant agent A provided.
3.7. Thermal Fuse comp. and Thermistor comp.
3.8. Pouring spout and lock lever A (knob for opening and closing the cover)
4x8 Deltite screws
  1. Remove the cover comp. 
  2. Remove the pouring spout. 
  3. Remove the lock lever A toward upper side by 
pushing it while pushing down. 
  4. Remove the container packing.
Point in Reassembling 
 
  When reassembling the pouring spout, insert the 
dowel of container comp. into the 2 long ribs. (refer to 
“Knob” in below diagram)
4x8 Deltite screws
Heater terminal
Nonfl ammable 
tube B
Clamps to hold 
spring A
Thermal fuse 
comp.
Thermistor 
comp.
Body comp.
Lock lever A
Knob
Pouring 
spout
Container packing
 
  The container packing shall closely contact the 
container fl ange without twisting or distortion.
NC-EH22_30_40P.indd   10
NC-EH22_30_40P.indd   10
1/14/08   9:36:24 AM
1/14/08   9:36:24 AM
Page of 20
Display

Click on the first or last page to see other NC-EH22P / NC-EH30P / NC-EH40P / NC-EH30PWTW / NC-EH40PWTW service manuals if exist.