NC-EG4000WTS, NC-EG3000WTS (serv.man3) - Panasonic Home Appliance Service Manual Simplified (repair manual). Page 15

Read Panasonic NC-EG4000WTS / NC-EG3000WTS (serv.man3) Service Manual Simplified online

15
5.5.6.
Lock/Unlock pad doesn’t work.
The items in the Check correspond to those shown in Check Point (
5.4.Check Point).
5.5.7.
Hot water cannot be poured out smoothly. Noise is getting big while operating and noisy. 
The Container is dirty with water stain.
Check
Diagnostic Method
Action
Lead wire assy. E
Is there connection in the lead wire assy. E? (0Ω)
Replace the Lead wire assy E.
When the above parts are normal
Replace the Control unit A comp.
(Operation)
Replace the Control unit B comp.
(Bottom)
Check
Diagnostic Method
Action
-
-
Wash with citric acid.
-
-
Replace the Control unit A comp.
(Operation)
Replace the Control unit B comp.
(Bottom)
Page of 26
Display