Read Panasonic MJ-L600STQ Service Manual online
14
<Switch position OFF>
<Switch position ON>
<Switch position REVERSE>
■
Solution
• Replace the switch
5.1.3.
Motor Diagnosis
■
Confirmation/Method
<Item 1> Motor (conductivity confirmation)
• Confirm the conducting state between two terminals (wiring terminals) of the motor.
<Item 2> Motor (running confirmation)
• Turn the spindle of the motor by hand to make sure that the spindle is not fixed.
■
Solution
• Replace the motor
Terminal
Number
1a
1
1b
2a
2
2b
1a
-
-
-
-
-
-
1
-
-
-
-
-
-
1b
-
-
-
-
-
-
2a
-
-
-
-
-
-
2
-
-
-
-
-
-
2b
-
-
-
-
-
-
Terminal
Number
1a
1
1b
2a
2
2b
1a
-
1.4Ω
-
-
-
-
1
1.4Ω
-
-
-
-
-
1b
-
-
-
-
-
-
2a
-
-
-
-
1.4Ω
-
2
-
-
-
1.4Ω
-
-
2b
-
-
-
-
-
-
Terminal
Number
1a
1
1b
2a
2
2b
1a
-
-
-
-
-
-
1
-
-
1.3Ω
-
-
-
1b
-
1.3Ω
-
-
-
-
2a
-
-
-
-
-
-
2
-
-
-
-
-
1.4Ω
2b
-
-
-
-
1.4Ω
-
Click on the first or last page to see other MJ-L600STQ service manuals if exist.