Read Panasonic MC-E7305 / MC-E7305K / MC-E7303 / MC-E7303K / MC-E7302 / MC-E7301 / MC-E7301K Service Manual online
CHECKPOINT
Power cord
Fuse (Plug for UK only)
Main fuse (250V, 12 A)
Motor continuity
ON/OFF Switch
Thermal cut-out
Triac
Power board
* Rotary potentiometer
Hose or Suction inlet,
Tubes and nozzle
Tubes and nozzle
Dust bag / Central filter
Motor fan
* Rotary potentiometer
* Power board
* Rotary potentiometer
CONDITION
Motor fails to rotate.
(no noise is heard at all).
(no noise is heard at all).
Motor runs but there is
no suction.
no suction.
Noise or vibration
Motor does not change
power (runs always at
full speed)
power (runs always at
full speed)
Motor runs irregularly
METHOD OF INSPECTION
Check power cord continuity.
Check plug fuse continuity.
Check main fuse continuity.
Check motor continuity between
carbon brush holder tabs.
carbon brush holder tabs.
Check continuity across ON/OFF
switch tabs.
switch tabs.
Check continuity across thermal
cut-out connection points.
(Assembled in motor)
cut-out connection points.
(Assembled in motor)
Check if the triac is in open circuit.
(Assembled in PCB)
(Assembled in PCB)
Check if the diac is in open circuit.
Check if the potentiometer is in
open circuit.
open circuit.
Check for any possible blockage in
the indicated parts .
the indicated parts .
Check if dust bag is full or central
filter is choked up.
filter is choked up.
Check dust accumulated in
motor fan.
motor fan.
Check possible bad contact of
power control potentiometer.
power control potentiometer.
Check if power board circuit is
short-circuited.
short-circuited.
Check possible bad contact of
power control potentiometer.
power control potentiometer.
CAUSE / REMEDY
If there is no continuity, replace
the power cord.
the power cord.
If there is no continuity, replace
the fuse.
the fuse.
If there is no continuity, replace
the main fuse.
the main fuse.
If there is no continuity, replace
the motor.
the motor.
If there is no continuity, replace
the switch.
the switch.
If there is no continuity, replace
the motor.
the motor.
If it is in open circuit, replace
power board ass’y.
power board ass’y.
If it is in open circuit, replace
power board ass’y.
power board ass’y.
If it is in open circuit, replace
power control.
power control.
If there is any blockage, remove it.
If dust bag is full, replace with a
new one. If central filter is choked
up, remove and clean it out or
replace.
new one. If central filter is choked
up, remove and clean it out or
replace.
If there is dust accumulated in the
motor fan, replace the motor and
check filter condition (never try to
dismantle the motor fan)
motor fan, replace the motor and
check filter condition (never try to
dismantle the motor fan)
If there is bad contact, replace the
power control.
power control.
If it is short-circuited, replace
power board ass’y.
power board ass’y.
If there is bad contact, replace
power control.
power control.
NOTE: Parts marked with (*) only affect to model with power control.
4 TROUBLE SHOOTING GUIDE
7
MC-E7305 / MC-E7305K / MC-E7303 / MC-E7303K / MC-E7302 / MC-E7301 / MC-E7301K
Click on the first or last page to see other MC-E7305 / MC-E7305K / MC-E7303 / MC-E7303K / MC-E7302 / MC-E7301 / MC-E7301K service manuals if exist.