11
3.6.
Mains Lead Assembly Replace-
ment
ment
3.6.1.
Removal
1. Refer to Handle Assembly Replacement Section.
2. With handle removed from body disassemble handle by
2. With handle removed from body disassemble handle by
removing fourteen (14) screws. Refer to Handle Assem-
bly Exploded View.
bly Exploded View.
3. Remove handle release button and spring.
4. Remove damaged lead.
4. Remove damaged lead.
3.6.2.
Installation
1. Replace damaged lead. carefully routing mains lead as
illustrated.
2. Reinstall handle as outlined in the handle installation sec-
tion.
3. Replace the cord stopper, the two (2) cord stopper screws
and the wire connectors.
NOTE: Never reuse a cord stopper. Always install a new cord
stopper whenever the old one is removed.
NOTE: For general servicing, it is necessary to eliminate pinch-
ing of any wire during reassembly. After servicing any electrical
component or electrical enclosure, the unit should be reassem-
bled and checked for dielectric breakdown or current leakage.
stopper whenever the old one is removed.
NOTE: For general servicing, it is necessary to eliminate pinch-
ing of any wire during reassembly. After servicing any electrical
component or electrical enclosure, the unit should be reassem-
bled and checked for dielectric breakdown or current leakage.
3.7.
ON/OFF Switch Replacement
3.7.1.
Removal
1. Remove the dust cover to expose the electrical connec-
tions of the ON/OFF switch.
2. Remove the insulated black wire lead from switch. Note
the location of the insulated lead when removing from
switch.
switch.
3. Remove uninsulated black wire from switch.
4. Remove the ON/OFF switch, (for ON/OFF switch replace-
4. Remove the ON/OFF switch, (for ON/OFF switch replace-
ment) by depressing the switch retaining tabs while push-
ing up out of the dust compartment at the same time.
3.7.2.
Installation
1. When re-connecting lead wires to ON/OFF switch make
sure the insulated lead is reconnected to its original loca-
tion as shown.
tion as shown.
3.8.
Motor Protector Replacement
3.8.1.
Removal
1. Remove the dust cover.
2. Remove the motor protector cover, by releasing one of
the tabs that secure it to the dust compartment. Take care
not to break the tabs during removal.
3.8.2.
Installation
1. Reinstall the motor protector and protector spring into the
dust compartment. Replace the motor protector cover by
applying pressure until both tabs snap into place.
applying pressure until both tabs snap into place.
NOTE: For general servicing, it is necessary to eliminate pinch-
ing of any wire during reassembly. After servicing any electrical
component or electrical enclosure, the unit should be reassem-
bled and checked for dielectric breakdown or current leakage.
ing of any wire during reassembly. After servicing any electrical
component or electrical enclosure, the unit should be reassem-
bled and checked for dielectric breakdown or current leakage.
Click on the first or last page to see other MC-E4053-00 service manuals if exist.