5
3 Troubleshooting Guide
CONDITION
CHECKPOINT
METHOD OF INSPECTION
CAUSE / REMEDY
Motor fails to rotate
(no noise is heard at all)
Power supply cord 
Check power supply cord continu-
ity.
If there is no continuity, replace the 
cord reel patition unit.
Fuse of P.C.B. Ass’y
(250V, 12A)
Check fuse continuity.
If there is no continuity, replace 
P.C.B. Ass’y.
Motor continuity
Check the conduction between the 
terminals of the motor.
If there is no continuity, replace the 
or motor.
ON/OFF 
Switch
Check continuity across switch
connections
If there is no continuity, replace
P.C.B. Ass’y.
Triac (Inside of P.C.B.)
Check if the triac is in open circuit. If it is in open circuit, replace 
P.C.B.Ass’y.
P.C.B. Ass’y
Check the internal parts for any-
thing unusual. (burn-out, melt-
down, etc.)
If anything is found unusual, 
replace the P.C.B. assembly with 
new one.
Motor runs but there is no suction
Hose or Suction inlet
Check if there is any blockage in 
the hose or suction inlet.
If there is any blockage, remove it.
Dust bog / Secondary filter
Check if dust bag is full or Second-
ary filter is choked up.
If dust bag is foll, replace with a 
new one. If Secondary filter is 
choked up, remove and clean it out 
or replace.
Noise or vibration
Motor fan
Check dust accumulated in motor 
fan (it could happen if the vacuum 
cleaner has been used without cen-
tral filter).
If there is dust accumulated in the 
motor fan, replace the motor and 
check filter condition. (never try to 
dismantle the motor fan)
Motor does not change power 
(runs always at full speed)
Power control
Adjust the power control and check 
whether or not the resistance var-
ies. (Gray
←→Blue)
If the resistance does not vary, then 
replace the P.C.B. Ass'y.
P.C.B. Ass’y
Examine the triac in the P.C.B. 
Ass'y and check whether or not T1 
and T2 are short-circuited.
If they are short-circuited, then 
replace the P.C.B. Ass'y.
Motor runs irregularly
P.C.B. Ass’y
Check possible bad contact of 
P.C.B. Ass’y.
Replace P.C.B. Ass’y.
Page of 18