EW-DE92-S820 - Panasonic Home Appliance Service Manual (repair manual). Page 7

Read Panasonic EW-DE92-S820 Service Manual online

7
4.2.
Procedure of very weak electric current testing (Driving block)
4.2.1.
Measure by the tester available for mA or 
µA.
1. Set the range at mA or 
µA.
2. Turn the switch ON without attaching the brush.
3. Touch the (-) terminal of tester with the driving shaft where connecting the brush and the (+) terminal of tester with the metal
terminal A.
4. Measure if the electric current is in between 0.04-0.12mA (40-120
µA) with NORMAL mode.  And confirm if the ion lamp may
glow.  It may be the failure if either the current value is out of range or no lit of ion panel.
NOTE:
• Measure more than three seconds later after switching ON.
• Confirm if the mode is selected NORMAL.
• Carefully touch the metal terminal A in order to prevent the deformation.
4.2.2.
Measure with the DC volt tester.
1. Turn the switch ON without attaching the brush.
2. Touch the (-) terminal of tester with the driving shaft where connecting the brush and the (+) terminal of tester with the metal
terminal A.
3. Measure if the direct current voltage is in between 10-30V with NORMAL mode.
NOTE:
• Measure more than three seconds later after switching ON.
• Confirm if the mode is selected NORMAL.
• Carefully touch the metal terminal A in order to prevent the deformation.
Page of 14
Display

Click on the first or last page to see other EW-DE92-S820 service manuals if exist.