- 32 - 
4. 
Push the On/off button and push the Leg massage button 
and check the maximum value in two minutes. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
5.  Check the pressures at three levels by the intensity 
adjustment of the Controller.    If the pressure values are in 
the range of the tolerance, the Air bag and the Pump unit 
are normal. 
* Each Air bags are checked as follows: 
- Leg Air bag large (right side brown hose with line) 
  Strong  22.5±7  
  Medium  13.7±7 
  Weak  6±4 
- Leg Air bag small/front (left side black hose with line) 
  Strong  24±7  
  Medium  14.5±7 
  Weak  8±5 
- Leg Air bag small/middle (left side black hose without line) 
  Strong  25.5±7  
  Medium  15.5±7 
  Weak  8±5 
- Leg Air bag small/back (right side brown hose without line) 
  Strong  21.5±7  
  Medium  12.5±7 
  Weak  7±4 
 