4.
Push the On/off button and push the Leg massage button
and check the maximum value in two minutes.
5. Check the pressures at three levels by the intensity
adjustment of the Controller. If the pressure values are in
the range of the tolerance, the Air bag and the Pump unit
are normal.
* Each Air bags are checked as follows:
- Leg Air bag large (right side brown hose with line)
Strong 22.5±7
Medium 13.7±7
Weak 6±4
- Leg Air bag small/front (left side black hose with line)
Strong 24±7
Medium 14.5±7
Weak 8±5
- Leg Air bag small/middle (left side black hose without line)
Strong 25.5±7
Medium 15.5±7
Weak 8±5
- Leg Air bag small/back (right side brown hose without line)
Strong 21.5±7
Medium 12.5±7
Weak 7±4