EH5571, EH5572, EH5573, EH5571K865, EH5573S865 - Panasonic Home Appliance Service Manual (repair manual). Page 16

Read Panasonic EH5571 / EH5572 / EH5573 / EH5571K865 / EH5573S865 Service Manual online

5   TROUBLESHOOTING  GUIDE
Refer to WIRING CONNECTION DIAGRAM.
 
To be continue
Hot air is not 
emitted at 
position 
Hot-3
Hot-2
Hot-1
Warm-3
Warm-2
Warm-1
Mild-3
Mild-2
Mild-1
or cool air is  
not emitted 
at position
Cool-3
Cool-2
Cool-1
< TROUBLE >
< CHECK >
< REMEDY >
Replace Heater
Block.
NG
Set Temp Switch and Main Switch to Hot-3
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 37.2
Ω
EH5571    : appox. 40.2
Ω
Set Temp Switch and Main Switch to Hot-2
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 42.7
Ω
EH5571    : appox. 45.3
Ω
Set Temp Switch and Main Switch to Hot-1
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 69.5
Ω
EH5571    : appox. 72.6
Ω
Set Temp Switch and Main Switch to Warm-3
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 50.8
Ω
EH5571    : appox. 56.0
Ω
Set Temp Switch and Main Switch to Warm-2
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 56.4
Ω
EH5571    : appox. 61.4
Ω
Set Temp Switch and Main Switch to Warm-1
Check the resistance of heater coil between 
conductor of Power cord
The value shoold be as follows:
EH5573.2 : appox. 83.1
Ω
EH5571    : appox. 88.5
Ω
16