1. Warning
Caution:
- Pb free solder has a higher melting point that standard solder; Typical the melting point is 50 - 70°F (30 - 40
℃) higher.
Please use soldering iron with temperature control and adjust it to 750 ±20°F (400 ± 10
℃).
In case of using high temperature soldering iron, please becareful not to heat too long.
- Pb free solder will tend to splash when heated too high (about 1100°F / 600
℃).
Power source
Power consumption
(" II - Hot ")
Air volume without nozzle
Air temperature without nozzle
(" II - Hot ")
Dimensions
Cord length
Weight
Supplied accessory
90 K (in case of room temperature 30°C)
(W) 90mm x (D) 220mm. x (H) 270mm.
(without power cord and nozzle)
2. Specifications
AC 220-240 V , 50~60 Hz
Code 865 = 1.7 m
Approx. =530g.
Set nozzle
AC 220 V, 50~60 Hz, 2100 W
AC 230 V, 50~60 Hz, 2300 W
AC 240 V, 50~60 Hz, 2500 W
1.9 m
3
/min
3. TROUBLESHOOTING GUIDE
Refer to WIRING CONNECTION DIAGRAM.
< TROUBLE >
< CHECK >
< REMEDY >
OK
<CHECK MOTOR HEATER BLOCK ASSEMBLY>
Check if there are odd objects between
joints of thermo switch or not
(Figure 3)
Remove the odd objects
between joints
Found odd object
No odd objects
Replace the
MOTOR HEATER ASSEMBLY
Figure 3
Thermo Switch
Hot air is not emitted
<CHECK COOL SWITCH BUTTON>
Check the conductivity between the terminal 1
and 2 by push and hold
the COOL SWITCH BUTTON
(Figure 2)
<CHECK TEMPERATURE SWITCH>
Check the conductivity between the terminal 2
and 4 by setting
the TEMPERATURE SWITCH to Position 2
(Figure 1)
Replace the
MAIN SWITCH
NG
OK
Replace the
COOL SWITCH BUTTON
NG
COOL SWITCH BUTTON
Lead Wire (Orange)
Lead Wire (Blue and Red)
For EH-NE81-84 only
Figure 2
Figure 1
Lead Wire (Black)
Lead Wire (Brown)
Lead Wire (Orange)
Temperature Switch
OK
3. TROUBLESHOOTING GUIDE
Refer to WIRING CONNECTION DIAGRAM.
< TROUBLE >
< CHECK >
< REMEDY >
Main body is
not operated
not operated
<CHECK POWER CORD>
Check the conductivity of power cord
<CHECK MAIN SWITCH>
Check the conductivity between the terminal 1
and 4 by setting
the MAIN SWITCH to Position 1
(Figure 4)
Replace the
MAIN SWITCH
Replace the
MOTOR HEATER
ASSEMBLY
NG
OK
NG
OK
Replace the
MOTOR HEATER
ASSEMBLY
Lead Wire (Yellow)
Lead Wire (Red)
Lead Wire (Gray)
Lead Wire (Orange)
*For code : 605, 655, 685, 695, 865
MAIN SWITCH
Figure 4