3. TROUBLESHOOTING  GUIDE
Refer to WIRING CONNECTION DIAGRAM.
LED at 140 º C
No operation 
(LED does not light)
< CHECKING PROCEDURE >
< CHECKING METHOD >
< REMEDY >
Check the Power cord.
Check the conductivity 
of Power cord.
Check the Power Switch
(0/1)
Hold the On/off switch (Tag Switch) 
pressed longer and check if  LED
(Power Lamp) lights. LED at * 140ºC 
will start blinking (LED will turn from 
BLINK to LIGHT after round one 
minute). 
LED light, but Iron 
Plate(Heater) 
does not become hot
Check Iron plate of Heater 
A : Housing side
Replace Heater A ass'y b/k
Check if resistance value between 
lead wires of the Housing side assy is 
approx. 20.0±1.0
Check the Lead Wire
Check connecting of Lead Wire
Replace Heater A ass'y b/k
or  Heater B ass'y b/k
Replace Heater B ass'y b/k
O
Check Circuit assembly b/k
Replace Circuit assembly 
b/k
LED dose not light , Iron 
Plate(Heater A,B) 
Replace Circuit assembly 
b/k
Check the Power Switch 
button of the Housing side
Check the operation of On/off Switch 
button of Housing side.
(Check if it works smoothly)
Replace the Power Cord
Figure1
Check Iron plate of Heater 
B : Press plate side
Check if resistance value between 
lead wires of the Press plate side 
assy is approx. 20.0±1.0
Replace the Housing A
Replace Circuit assembly 
b/k
O
N
N
N
O
O
N
N
N
N
N
O
O