UF-585, UF-595 (serv.man2) - Panasonic Fax Service Manual (repair manual). Page 126

Read Panasonic UF-585 / UF-595 (serv.man2) Service Manual online

Troubleshooting
131
4.6.2
Poor Transmitted Copy Quality
START
Yes
Make a copy.
No
No
Yes
Is the printed copy normal?
Perform a transmission test
to a reference fax unit.
Is the LED Array lit?
Does CN1, pin 1 on the 
SCA/SCB PCB measure
+24 VDC? 
Yes
No
Yes
No
Are CN7 (SCA/SCB PCB) 
and CN30 (CCD PCB)
connected  properly?
Connect them correctly.
Replace the LVPS.
Does nLEDON go Low 
when the scan starts?
Check CN1 on the SCA/
SCB PCB and the LED
harness. 
Does the problem still
occur?
Replace the LED Array.
The receiving unit may be
defective.
1. Replace the Scanner
    Block.
2. Replace the SCA/SCB PCB.
Replace the SCA/SCB PCB.
Is the transmitted copy
normal?
No
Yes
No
No
1. Check CN8 (SCA/SCB PCB)
    and CN25 (LCU PCB).
2. Check the telephone line cable.
    Replace if necessary.
Does poor transmitted copy
appear when transmitting to
a specific receiver?
Telephone line quality is
poor.
END
Yes
Yes
Page of 127