KX-MB1900UCB, KX-MB2020UCB (serv.man2) - Panasonic Fax Service Manual (repair manual). Page 121

Read Panasonic KX-MB1900UCB / KX-MB2020UCB (serv.man2) Service Manual online

121
KX-MB1900UCB/KX-MB2020UCB
12.3.6.3. CALL SERVICE 3
"CALL SERVICE 3" means that the temperature of the fuser does not rise up to or exceed a constant temperature.
The temperature is monitored with the thermistor inside the fuser and detected with the voltage input into IC 300-D19.
* When Call Service 3 is occurred, the cause can be distinguished by service mode  655.
Refer to CALL SERVICE Troubleshooting Guide (P.118) for details.