KX-FPC135, KX-FPC141 - Panasonic Fax Service Manual (repair manual)

kx-fpc135, kx-fpc141 service manual
Model
KX-FPC135 KX-FPC141
Pages
127
Size
8.02 MB
Type
PDF
Document
Service Manual
Brand
Device
Fax / CORDLESS
File
kx-fpc135-kx-fpc141.pdf
Date

Read Panasonic KX-FPC135 / KX-FPC141 Service Manual online

KX-FPC135
KX-FPC141
(for U.S.A.)
Plain Paper FAX With 900 MHz Cordless Phone
ORDER NO. KM79906281C1
F7
 1 
INTRODUCTION 
4
 1.1. 
SAFETY PRECAUTIONS 
4
 1.2. 
INSULATION RESISTANCE TEST 
4
 1.3. 
FOR SERVICE TECHNICIANS 
4
 1.4. 
BATTERY CAUTION 
4
 1.5. 
AC CAUTION 
5
 1.6. 
PERSONAL SAFETY PRECAUTIONS 
5
 1.7. 
SERVICE PRECAUTIONS 
6
 1.8. 
FEATURES 
7
 1.9. 
SPECIFICATIONS 
8
 1.10. OPTIONAL ACCESSORIES 
9
 1.11. CCITT No. 1 Test Chart (Actual size) 
10
 1.12. LOCATION OF CONTROLS 
11
 1.13. CONNECTIONS 
16
 1.14. INSTALLATION 
18
 1.15. MAINTENANCE ITEMS AND COMPONENT LOCATIONS
 
28
 2 
TROUBLESHOOTING GUIDE 
32
 2.1. 
TROUBLESHOOTING SUMMARY 
32
 2.2. 
USER RECOVERABLE ERRORS 
33
 2.3. 
TROUBLESHOOTING DETAILS 
36
 2.4. 
PROGRAMMING AND LISTS 
101
 2.5. 
TEST FUNCTIONS 
116
 3 
ADJUSTMENTS 
122
 3.1. 
TABLE OF TEST EQUIPMENT AND TOOLS 
122
 3.2. 
ADJUSTING THE FEEDER PRESSURE 
122
 3.3. 
CONFIRMING THE SEPARATION SPRING 
122
 3.4. 
DOCUMENT READ START POSITION ADJUSTMENT 
123
 3.5. 
CORDLESS BASE BOARD 
124
 3.6. 
Objective 
127
 3.7. 
General Information 
127
 3.8. 
Equipment 
127
 3.9. 
Handset Preparation 
127
 3.10. Symptom/Remedy Table 
127
 3.11. Handset Adjustment Preparation 
127
 3.12. Adjustment Procedure 
128
 3.13. Handset Reference Drawing 
129
 4 
HOW TO CHECK THE RF UNIT 
130
 4.1. 
Handset 
130
 5 
DISASSEMBLY INSTRUCTIONS 
131
 6 
HOW TO REPLACE THE FLAT PACKAGE IC 
145
 6.1. 
PREPARATION 
145
 6.2. 
FLAT PACKAGE IC REMOVAL PROCEDURE 
145
 6.3. 
FLAT PACKAGE IC INSTALLATION PROCEDURE  146
 6.4. 
BRIDGE MODIFICATION PROCEDURE 
146
 7 
CIRCUIT OPERATIONS 
147
 7.1. 
CONNECTION DIAGRAM 
147
 7.2. 
GENERAL BLOCK DIAGRAM 
148
 7.3. 
CONTROL SECTION 
150
 7.4. 
FACSIMILE SECTION 
161
 7.5. 
SENSORS AND SWITCHES 
176
 7.6. 
MODEM SECTION 
180
 7.7. 
DESCRIPTION OF BLOCK DIAGRAM IN ANALOG
SECTION 
187
 7.8. 
NCU SECTION 
189
 7.9. 
ITS (Integrated telephone System) and MONITOR
SECTION (for KX-FPC135) 
193
 7.10. ITS (Integrated telephone System) and MONITOR
SECTION (for KX-FPC141) 
194
 7.11. ATAS (Automatic Telephone Answering System)
SECTION 
194
 7.12. TAM INTERFACE SECTION (for KX-FPC135 only) 
195
 7.13. OPERATION BOARD SECTION 
197
 7.14. LCD SECTION 
198
 7.15. POWER SUPPLY BOARD SECTION 
199
 8 
CORDLESS SECTION 
202
 8.1. 
Charge Circuit 
202
 8.2. 
Line Sending Signal 
202
 8.3. 
Line Receiving Signal 
203
 8.4. 
RX Data Circuit 
203
 8.5. 
ID Code Setting 
203
 9 
HANDSET SECTION 
204
 9.1. 
Block diagram 
204
 9.2. 
Carrier detection circuit 
206
 9.3. 
Security code 
207
 9.4. 
CPU DATA 
208
 9.5. 
BLOCK DIAGRAM (Handset) 
209
 9.6. 
NEW CIRCUIT OPERATION (Handset) 
210
 10 EXPLANATION OF CPU DATA COMMUNICATION 
212
 10.1. Calling 
212
 10.2. To Terminate Communication 
212
 10.3. Ringing 
212
 10.4. Ports for Transmitting and Receiving of Data 
212
 10.5. Waveform of DATA Used for Cordless Transmission and
Reception 
213
 10.6. When LINKing 
214
 10.7. Pulse Dial 
214
 10.8. Tone Dial 
214
 10.9. FREQUENCY TABLE (MHz) 
214
 11 FOR THE SCHEMATIC DIAGRAMS 
215
 11.1. MEMO 
216
 12 PRINTED CIRCUIT BOARD (DIGITAL BOARD) 
217
 12.1. PRINTED CIRCUIT BOARD 
217
 12.2. PRINTED CIRCUIT DIAGRAM (DIGITAL BOARD) 
218
 13 PRINTED CIRCUIT BOARD (ANALOG BOARD) 
219
 13.1. PRINTED CIRCUIT BOARD 
219
 13.2. PRINTED CIRCUIT BOARD 
220
 14 PRINTED CIRCUIT BOARD (OPERATION BOARD) 
221
 15 PRINTED CIRCUIT BOARD (SWITCHING POWER SUPPLY) 223
 16 PRINTED CIRCUIT BOARD (HANDSET BOARD AND CHARGE
BOARD) 
225
 17 SCHEMATIC DIAGRAM (DIGITAL BOARD) 
227
CONTENTS
 Page 
Page
2
KX-FPC135 / KX-FPC141
 17.1. SCHEMATIC DISGRAM (DIGITAL BOARD) (KX-FPC135)
 
227
 17.2. SCHEMATIC DISGRAM (DIGITAL BOARD) (KX-FPC141)
 
228
 18 SCHEMATIC DISGRAM (ANALOG BOARD) (KX-FPC135) 
229
 18.1. SCHEMATIC DISGRAM (ANALOG BOARD) (KX-FPC135)
 
229
 18.2. SCHEMATIC DISGRAM (ANALOG BOARD) (KX-FPC141)
 
230
 19 SCHEMATIC DIAGRAM (OPERATION BOARD) 
231
 19.1. SCHEMATIC DISGRAM (OPERATION BOARD) (KX-
FPC135) 
231
 19.2. SCHEMATIC DISGRAM (OPERATION BOARD) (KX-
FPC141) 
232
 20 SCHEMATIC DIAGRAM (SWITCHING POWER SUPPLY) 
233
 21 SCHEMATIC DIAGRAM (HANDSET BOARD AND CHARGE) 235
 21.1. SCHEMATIC DIAGRAM (HANDSET BOARD AND
CHARGE) (KX-FPC135) 
235
 21.2. SCHEMATIC DIAGRAM (HANDSET BOARD AND
CHARGE) (KX-FPC141) 
236
 22 TERMINAL GUIDE OF THE IC´S TRANSISTORS AND DIODES
 
237
 23 FIXTURES AND TOOLS 
238
 24 CABINET, MECHANICAL AND ELECTRICAL PARTS
LOCATION 
239
 24.1. OPERATION PANEL SECTION 
239
 24.2. UPPER CABINET SECTION 
240
 24.3. LOWER/P.C.B. SECTION 
242
 24.4. MOTOR SECTION 
243
 24.5. HANDSET SECTION 
244
 24.6. ACTUAL SIZE OF SCREWS AND WASHER 
245
 25 ACCESSORIES AND PACKING MATERIALS 
246
 26 REPLACEMENT PARTS LIST 
247
 26.1. CABINET AND ELECTRICAL PARTS 
247
 26.2. DIGITAL BOARD PARTS 
249
 26.3. ANALOG BOARD PARTS 
254
 26.4. OPERATION BOARD PARTS 
259
 26.5. POWER SUPPLY BOARD PARTS 
260
 26.6. CHARGE BOARD 
261
 26.7. HANDSET BOARD 
261
 26.8. FIXTURES AND TOOLS 
263
3
KX-FPC135 / KX-FPC141
1 INTRODUCTION
1.1.  SAFETY PRECAUTIONS
 1. Before servicing, unplug the AC power cord to prevent an electric shock.
 2. When replacing parts, use only the manufacturer´s recommended components.
 3. Check the condition of the power cord. Replace if wear or damage is evident.
 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
 5. Before returning the serviced equipment to the customer, be sure to perform the following insulation resistance test to prevent
the customer from being exposed to shock hazards.
1.2. INSULATION RESISTANCE TEST
 1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
 2. Turn on the power switch.
 3. Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metal cabinet part
(screwheads, control shafts, bottom frame, etc.).
Note: Some exposed parts may be isolated from the chassis by design. These will read infinity.
 4. If the measurement is outside the specified limits, there is a possibility of a shock hazard.
1.3. FOR SERVICE TECHNICIANS
ICs and LSIs are vulnerable to static electricity.
When repairing, the following precautions will help prevent recurring malfunctions.
 1. Cover the plastic part´s boxes with aluminum foil.
 2. Ground the soldering irons.
 3. Use a conductive mat on the worktable.
 4. Do not touch the IC or LSI pins with bare fingers.
1.4.  BATTERY CAUTION
CAUTION
Danger of explosion if the battery is replaced incorrectly. Replace only with the same or equivalent type recommended by the
manufacturer. Discard used batteries according to following caution:
Disposal of lithium batteries should be performed by permitted, professional disposal firms knowledgeable in state government
federal and local hazardous materials and hazardous waste transportation and disposal requirements.
A battery continues to have no transportation limitations as long as it is separated to prevent short circuits and packed in strong
packaging.
Commercial firms that dispose of any quantity of lithium cells should have a mechanism in place to account for their ultimate
disposition. This is a good practice for all types of commercial or industrial waste.
Recommend Type Number:
CR2032 (BATT) Manufactured by MATSUSHITA
CR2032 (BATT) Manufactured by SONY
4
KX-FPC135 / KX-FPC141
Page of 127
Display

Download Panasonic KX-FPC135 / KX-FPC141 Service Manual (Repair Manual)

Here you can read online and download Panasonic KX-FPC135 / KX-FPC141 Service Manual in PDF. KX-FPC135 / KX-FPC141 service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic KX-FPC135 / KX-FPC141 Fax. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.