KX-FP143UA - Panasonic Fax Service Manual (repair manual). Page 121

Read Panasonic KX-FP143UA Service Manual online

6.7.8. POWER SUPPLY BOARD SECTION
6.7.8.1. Key components for troubleshooting
Check the following parts first: F101, D101-D104, C106, Q101, PC101 and IC101.
This comes from our experience with experimental tests. For example: power supply and lightning surge voltage test, withstanding
voltage test, intentional short circuit test, etc.
Caution:
If you find a melted fuse in the unit, do not turn on the power until you locate and repair the faulty parts (except for the fuse);
otherwise the fuse will melt again and you cannot pinpoint the faulty point.
In most cases, the symptom is that nothing is output. It is more likely that the fault is in the primary side rather than the secondary
side. Check the primary side first.
Input
Circuit
AC
Input
Surge
Absorber
Circuit
G
H
5V
24V
Kick-on
Voltage
Circuit
E
IC101
F
GND
Control
Circuit
R136
R137
Converter
Circuit
C
D
5V
Output
Circuit
24V
Output
Circuit
+
-
Rectifier
Circuit
A
B
C106
Error Detecting
Circuit
POWER SUPPLY BLOCK DIAGRAM
DUMMY LOAD to check voltage
1
2
3
4
5
6
7
V
V
V
GND
5V
24V
CN301
24.5V
±
0.5V
5.0V
±
0.25V
: Volt Meter
When you check voltage in
a power supply unit alone,
use this dummy load.
If the dummy load is not
available, connect the main 
P.C.B. to the analog P.C.B.
Surge
Absorber
Circuit
121
KX-FP143UA
Page of 127