Read Panasonic KX-FLB813RU (serv.man7) Service Manual Supplement online
ORDER NO. KMF0802602SE
Flat-Bed Multi-Function Laser Fax
Model No.
KX-FLB813RU
(for Russia)
TABLE OF CONTENTS
PAGE
1 REPLACEMENT PARTS LIST--------------------------------- 2
1.1. REFERENCE CHART------------------------------------ 2
1.2. ORIGINAL AND NEW PARTS COMPARISON
1.2. ORIGINAL AND NEW PARTS COMPARISON
LISTS --------------------------------------------------------- 2
1.3. Description for Change----------------------------------- 3
2 CORRECTION------------------------------------------------------ 4
2.1. LOWER CABINET SECTION (3)---------------------- 4
Please file and use this supplement manual together with the service manual for Model No.KX-FLB813RU,
Order No.KMF0606989CE.
Order No.KMF0606989CE.
2
KX-FLB813RU
1 REPLACEMENT PARTS LIST
1.1.
REFERENCE CHART
1.2.
ORIGINAL AND NEW PARTS COMPARISON LISTS
Q Change of the Suffix Code
Serial No.Label tells you the suffix code as follows.
ORefer to Description for Change (P.3).
Reason for Change
*The following items (1-8) indicate the reason for change. See the “Notes” column for each part in ORIGINAL AND NEW PARTS
COMPARISON LISTS.
1. Improve performance
*The following items (1-8) indicate the reason for change. See the “Notes” column for each part in ORIGINAL AND NEW PARTS
COMPARISON LISTS.
1. Improve performance
Remark:
*a :To share the parts with other models
*a :To share the parts with other models
2. Change of material or dimension
3. To meet approved specification
4. Standardization
5. Addition
6. Deletion
7. Correction
8. Other
3. To meet approved specification
4. Standardization
5. Addition
6. Deletion
7. Correction
8. Other
Ref. No.
Part No.
Part Name & Description
Pcs/
Set
Remarks
Notes
Time of Change
Original (Old)
New
(Suffix)
LOWER CABINET SECTION
493
493
LPA1604K
LPA1622K
LASER UNIT
1
*a
4
W
---
HIGH VOLTAGE POWER BOARD
PCB16
PCB16
----------
N0GG4E000007
HIGH VOLTAGE POWER BOARD
1
*a
5
Y
A to B
3
KX-FLB813RU
1.3.
Description for Change
OLD
NEW
OLD
NEW
When replacing HVPS
When replacing LSU
Molding type
transformer
transformer
Molding type
transformer
transformer
Output terminal
Output terminal
connector
Output terminal
Output terminal
Open type
transformer
transformer
Open type
transformer
transformer
connector
Old type
New type
How to distinguish Old type from New type (HVPS)
Is HVPS a new type
or an old type?
Is HVPS a new type
or an old type?
When replacing Base Cabinet
Only the new type
of LSU can be used.
of LSU can be used.
Only the new
type of HVPS
can be used.
type of HVPS
can be used.
Old type of
HVPS only can
be used.
HVPS only can
be used.
Both the new and
old types of LSU
can be used.
old types of LSU
can be used.
(N0GG4E000004)
(N0GG4E000007)
N0GG4E000004:OK
N0GG4E000007:OK
N0GG4E000004:NG
N0GG4E000004:NG
N0GG4E000007:NG
Only the new type of Base Cabinet is provided.
It does not matter if HVPS is an old type or a new type.
It does not matter if HVPS is an old type or a new type.
High Voltage Power Board (HVPS) and LSU have two kinds respectively, an old type and a new type.
When replacing HVPS or LSU, first confirm if HVPS is a new type or an old type,
then proceed with the service according to the following flow chart.
If the combination is wrong, it does not work properly.
When replacing HVPS or LSU, first confirm if HVPS is a new type or an old type,
then proceed with the service according to the following flow chart.
If the combination is wrong, it does not work properly.
New type
How to distinguish Old type from New type (LSU)
Old type
LPA1604K Suffix No.2
LPA1604K Suffix No.1
LPA1622K
4
KX-FLB813RU
2 CORRECTION
2.1.
LOWER CABINET SECTION (3)
[Changed from original section "19.2.1.13. LOWER CABINET SECTION (3)"]
K.T.
KXFLB813RU