SP phone Audio Check
and Confirmation
-
 1. 
Link to Base which is connected to Line Simulator.
 2. 
Set line voltage to 48V and line current to 40mA.
 3. 
Set the handset off-hook using SP-Phone key.
 4. 
Input -25dBm/1KHz to Line I/F and measure Receiving level at SP1 and SP2.
 5. 
Confirm that the level is -15.5dBm ± 2dBm and that the distortion level is < 5%.
(vol = 3)
IC1, C37, C68,
C91, R25,
R26, C20,
C12, C87,
C109, R85,
C103, C10,
C17, R86,
R29, R37,
R38, L6, L7,
C79, C78