KX-FC268RU-T - Panasonic Fax Service Manual (repair manual). Page 9

Read Panasonic KX-FC268RU-T Service Manual online

9
KX-FC268RU-T
2.3.
Insulation Resistance Test
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with an ohmmeter between the jumpered AC plug and each exposed metal cabinet part
(screw heads, control shafts, bottom frame, etc.).
Note: Some exposed parts may be isolated from the chassis by design. These will read infinity.
4. If the measurement is outside the specified limits, there is a possibility of a shock hazard.
2.4.
Battery Caution
CAUTION
Danger of explosion if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the manufacturer’s instructions.
2.4.1.
Information for Users on Collection and Disposal of Old Equipment
and used Batteries
These symbols ((1), (2), (3)) on the products, packaging, and/or accompanying documents mean that used electrical and elec-
tronic products and batteries should not be mixed with general household waste.
For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection
points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC.
By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential nega-
tive effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more
information about collection and recycling of old products and batteries, please contact your local municipality, your waste dis-
posal service or the point of sale where you purchased the items.
Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
Information on Disposal in other Countries outside the European Union
These symbols ((1), (2), (3)) are only valid in the European Union. If you wish to discard these items, please contact your local
authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol
This symbol ((2)) might be used in combination with a chemical symbol ((3)). In this case it complies with the requirement set by
the Directive for the chemical involved.
2.5.
Note for Repairing
Caution
Please inform users of the danger of data being lost at the time of repair.
Data will be lost in the following situations.
1. When replacing the ROM ass'y.
2. When replacing the Main board ass'y.
3. When executing mode #550 or #710.
There is a possibility of data loss in the following situations.
1. When removing a board.
2. When writing new software to ROM.
Page of 127