KX-FC195RU-G (serv.man3) - Panasonic Fax Service Manual Supplement (repair manual). Page 2

Read Panasonic KX-FC195RU-G (serv.man3) Service Manual Supplement online

1 REPLACEMENT PARTS LISTS
1.1. REFERENCE CHART
Reason for Change
*The following items (1-8) indicate the reason for change. See the “Notes” column for each part in ORIGINAL AND NEW PARTS
COMPARISON LISTS 
.
1. Improve performance
Remarks:
*a: 
To correct error writing.
*b: To share the parts with other models.
*c: To improve the quality.
*d: To improve the Caller ID circuit.
*e: Sales section’s request.
2. Change of material or dimension
3. To meet approved specification
4. Standardization
5. Addition
6. Deletion
7. Correction
8. Other
Interchangeability Code
**The following items (V-Z) indicate the interchangeability. See the “Notes” column for each part in ORIGINAL AND NEW PARTS COMPARISON
LISTS 
.
Parts
Set Production
V Original
New
Early (before change)
Late (after change)
Original or new parts may be used in early or late production set.
Use original parts until exhausted, then stock new parts.
W Original
New
Early (before change)
Late (after change)
Original parts may be used in early production sets only. New parts may be used in early or
late production sets. Use original parts where possible, then stock new parts.
X Original
New
Early (before change)
Late (after change)
New parts only may be used in early or late production sets.
Stock new parts.
Y Original
New
Early (before change)
Late (after change)
Original parts may be used in early production sets only. New parts may be used in late
production sets only. Stock both original and new parts.
Z Other
Note:
Alphabets in the “Remarks” column in the following lists correspond to the alphabets in the “Remarks” in REFERENCE
CHART
.
1.2. ORIGINAL AND NEW PARTS COMPARISON LISTS
Change of the Suffix Code
Suffix Code
Reasons of change
Base Unit
Portable Handset
----------
A
B
In order to conform to other model conditions.
A
B
B
C
The factory mode is changed to reduce the noise. There is no change in the replacement parts list.
B
C
----------
The Cordless Base Board (PCB5) is changed to improve the Caller ID data receiving.
Serial No.Label tells you the suffix code as follows.
Ref No.
Part No.
Part Name & Descriptions
Pcs/Set
Remarks
Notes
Suffix
Original (Old)
New
CABINET AND ELECTRICAL PARTS
61
PFGT2252Z-M
PFGT2252Y-M
NAME PLATE
1
*e
8
X
ACCESSORIES AND PACKING MATERIALS
A6
PFQX1877Z
PFQX1877Y
INSTRUCTION BOOK
1
*e
8
X
P1
PFPE1473Y-M
PFPE1473X-M
GIFT BOX ASS’Y
1
*e
8
X
ANALOG BOARD PARTS
D141
PQVDMZJ4R7A
--------
DIODE (SI)
*1
0
*d
6
X
SA103
PFRZ001Z
--------
SURGE ABSORBER
*1
0
*d
6
X
J159
----------
EXCELDR35
COMPONENTS PARTS
*1
1
*d
5
X
C279
----------
ECKDKX471KB
CAPACITOR, 470pF
*1
1
*d
5
X
CORDLESS BASE BOARD PARTS
PCB5
PFLP1468RUZ
PFLP1468RUY
CORDLESS BASE BOARD ASS’Y (RTL)
(Refer to NEW CORDLESS BASE BOARD.)
1
*c
1
X
B
C
2
KX-FC195RU-G
Page of 14
Display