Read Panasonic SV-AV10U / SV-AV10E / SV-AV10B / SV-AV10EN (serv.man2) Service Manual online
2002
SV-AV10U
SV-AV10E
SV-AV10B
SV-AV10EN
SV-AV10E
SV-AV10B
SV-AV10EN
VOL. 2
Colour
(S) ...... Silver Type
(A) ...... Blue Type
(R) ...... Red Type (Only SV-AV10U)
(S) ...... Silver Type
(A) ...... Blue Type
(R) ...... Red Type (Only SV-AV10U)
SD Multi AV Device
ORDER NO.VMD0202014C0
CODE. A09
1 INTRODUCTION
3
1.1.
INTRODUCTION
3
2 SAFETY PRECAUTIONS
3
2.1.
GENERAL GUIDELINES
3
2.2.
LEAKAGE CURRENT COLD CHECK
3
2.3.
LEAKAGE CURRENT HOT CHECK (See Figure. 1)
3
3 PREVENTION OF ELECTRO STATIC DISCHARGE (ESD) TO
ELECTROSTATICALLY SENSITIVE (ES) DEVICES
4
4 HOW TO REPLACE THE LITHIUM BATTERY
5
4.1.
REPLACEMENT PROCEDURE
5
5 HOW TO RECYCLE THE LITHIUM BATTERY (U.S.ONLY)
6
6 BLOCK DIAGRAM
7
6.1.
CAMERA BLOCK DIAGRAM
7
6.2.
CONTROL BLOCK DIAGRAM
8
6.3.
DSC BLOCK DIAGRAM
9
6.4.
MONITOR BLOCK DIAGRAM
10
7 SCHEMATIC DIAGRAM
11
7.1.
MAIN CONNECTION SCHEMATIC DIAGRAM
11
7.2.
CAMERA I/F SCHEMATIC DIAGRAM
13
7.3.
ENCODER SCHEMATIC DIAGRAM
14
7.4.
DSC SCHEMATIC DIAGRAM
15
7.5.
LCD SCHEMATIC DIAGRAM
19
7.6.
CONTROL SCHEMATIC DIAGRAM
20
7.7.
EX INPUT SCHEMATIC DIAGRAM
23
8 CIRCUIT BOARD ASSEMBLIES
25
8.1.
MAIN C.B.A.
25
9 CHECKING POINT OF THE CSP IC
27
9.1.
CHECKING POINT TABLE
27
9.2.
WAVEFORM TABLE (PLAY MODE)
34
10 REPLACEMENT PARTS LIST
39
10.1. ELECTRICAL PARTS LIST
39
CONTENTS
Page
Page
2
SV-AV10U / SV-AV10E / SV-AV10B / SV-AV10EN
2.1. GENERAL GUIDELINES
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essential
that these critical parts should
that these critical parts should
be replaced with
manufacturer’s specified parts to prevent X-RADIATION,
shock fire, or other hazards. Do not modify the original
design without permission of manufacturer.
shock fire, or other hazards. Do not modify the original
design without permission of manufacturer.
2. An Isolation Transformer should always be used during the
servicing of AC Adaptor whose chassis is not isolated from
the AC power line. Use a transformer of adequate power
rating as this protects the technician from accidents
resulting in personal injury from electrical shocks. It will also
protect AC Adaptor from being damaged by accidental
shorting that may occur during servicing.
the AC power line. Use a transformer of adequate power
rating as this protects the technician from accidents
resulting in personal injury from electrical shocks. It will also
protect AC Adaptor from being damaged by accidental
shorting that may occur during servicing.
3. When servicing, observe the original lead dress. It a short
circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
overheated or damaged by the short circuit.
4. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers shields are properly
installed.
installed.
5. After servicing, make the following leakage current checks
to prevent the customer from being exposed to shock
hazards.
hazards.
2.2. LEAKAGE CURRENT COLD
CHECK
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1M
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1M
Ω and 5.2MΩ. When the exposed metal does not have
a return path to the chassis, the reading must be infinity.
2.3. LEAKAGE CURRENT HOT
CHECK (See Figure. 1)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5 k
Ω, 10 W resistor, in parallel with a 0.15 µF
capacitor, between each exposed metallic part on the set
and a good earth ground, as shown in Figure. 1.
and a good earth ground, as shown in Figure. 1.
3. Use an AC voltmeter, with 1 k
Ω/V or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equivalent)
may be used to make the hot checks, leakage current must
not exceed 1/2 mA. In case a measurement is outside of
the limits specified, there is a possibility of a shock hazard,
and the equipment should be repaired and rechecked
before it is returned to the customer.
may be used to make the hot checks, leakage current must
not exceed 1/2 mA. In case a measurement is outside of
the limits specified, there is a possibility of a shock hazard,
and the equipment should be repaired and rechecked
before it is returned to the customer.
Figure. 1
1 INTRODUCTION
1.1. INTRODUCTION
This service manual contains technical information, which allow service personnel´s to understand and service this model.Please
place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
2 SAFETY PRECAUTIONS
3
SV-AV10U / SV-AV10E / SV-AV10B / SV-AV10EN
3 PREVENTION OF ELECTRO STATIC DISCHARGE (ESD)
TO ELECTROSTATICALLY SENSITIVE (ES) DEVICES
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component damage
caused by electro static discharge (ESD).
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component damage
caused by electro static discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any ESD on your
body by touching a known earth ground. Alternatively, obtain and wear a commercially available discharging ESD wrist strap,
which should be removed for potential shock reasons prior to applying power to the unit under test.
which should be removed for potential shock reasons prior to applying power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as
aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an antistatic solder removal device. Some solder removal devices not classified as “antistatic (ESD protected)” can
4. Use only an antistatic solder removal device. Some solder removal devices not classified as “antistatic (ESD protected)” can
generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most
replacement ES devices are packaged with leads electrically shorted together by conductive foam, aluminum foil or comparable
conductive material).
conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective material
to the chassis or circuit assembly into which the device will be installed.
CAUTION:
CAUTION:
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise harmless motion such as the
brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate static electricity (ESD)
sufficient to damage an ES device).
sufficient to damage an ES device).
4
SV-AV10U / SV-AV10E / SV-AV10B / SV-AV10EN