2.1. GENERAL GUIDELINES
 1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essential
that
these
critical
parts
should
be
replaced
with
manufacturer’s specified parts to prevent X-RADIATION,
shock fire, or other hazards. Do not modify the original
design without permission of manufacturer.
 2. An Isolation Transformer should always be used during the
servicing of AC Adaptor whose chassis is not isolated from
the AC power line. Use a transformer of adequate power
rating as this protects the technician from accidents
resulting in personal injury from electrical shocks. It will also
protect AC Adaptor from being damaged by accidental
shorting that may occur during servicing.
 3. When servicing, observe the original lead dress. It a short
circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
 4. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers shields are properly
installed.
 5. After servicing, make the following leakage current checks
to prevent the customer from being exposed to shock
hazards.
2.2. LEAKAGE CURRENT COLD
CHECK
 1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
 2. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the equipment such as screwheads, connectors,
control shafts, etc. When the exposed metallic part has a
return path to the chassis, the reading should be between
1M
and 5.2M
. When the exposed metal does not have
a return path to the chassis, the reading must be infinity.
1 INTRODUCTION
1.1. INTRODUCTION
This service manual contains technical information, which allow service personnel´s to understand and service this model.Please
place orders using the parts list and not the drawing reference numbers.
If the circuit is changed or modified, the information will be followed by service manual to be controlled with original service manual.
1.2. ABOUT LEAD FREE SOLDER (PbF)
Distinction of PbF PCB: PCBs (manufactured) using lead free solder will have a PdF stamp on the PCB.
Caution:
 
·
 
Pb free solder has a higher melting point than standard solder, Typically the melting point is 50-70°F (30-40°C) higher.
Please use a high temperature soldering iron. In case of soldering iron with temperature control, please set it to 700±20°F
(370±10°C).
 
·
 
Pb free solder will tend to splash when heated too high (about 1100°F/ 600°C).
When soldering or unsoldering, please completely remove all of the solder on the pins or solder area, and be sure to heat the