DMC-LZ10P, DMC-LZ10PC, DMC-LZ10PL, DMC-LZ10E, DMC-LZ10EB, DMC-LZ10EE, DMC-LZ10EF, DMC-LZ10EG, DMC-LZ10GC, DMC-LZ10GK, DMC-LZ10GN, DMC-LZ10EE9S, DMC-LZ10EE9K - Panasonic Digital Camera Service Manual (repair manual). Page 16

Read Panasonic DMC-LZ10P / DMC-LZ10PC / DMC-LZ10PL / DMC-LZ10E / DMC-LZ10EB / DMC-LZ10EE / DMC-LZ10EF / DMC-LZ10EG / DMC-LZ10GC / DMC-LZ10GK / DMC-LZ10GN / DMC-LZ10EE9S / DMC-LZ10EE9K Service Manual online

16
About "*" indication in the above table:
The third digit from the left is different as follows.
- In case of 0 (example: 18001000)
When the third digit from the left shows "0", this error occurred under the condition of INITIAL SETTINGS has been 
completed.
It means that this error is occurred basically at user side.
- In case of 8 (example: 18801000)
When the third digit from the left shows "8", this error occurred under the condition of INITIAL SETTINGS has been
released. 
(Example; Factory assembling-line before unit shipment, Service mode etc.)
It means that this error is occurred at service side.
• 6. How to returned to Normal Display:
Turn the power off and on, to exit from Error code display mode.
NOTE:
The error code can not be initialized.
HARD
VENUS A/D
Flash
20*0
0000
Flash charging error.
IC6001-(AC17) signal line or Flash charging circuit
FLASH ROM
(EEPROM 
Area)
FLASH ROM
(EEPROM 
Area)
2B*0
0001
EEPROM read error
IC6002 (FLASH ROM)
0002
EEPROM write error
IC6002 (FLASH ROM)
SYSTEM
RTC
2C*0
0001
SYSTEM IC initialize failure error
Communication between IC6001 (VENUS 4) and IC9101 (SYSTEM)
SOFT
CPU
Reset
30*0
0001
|
0007
NMI reset
Non Mask-able Interrupt
(30000001-30000007 are caused by factors)
Card
Card
31*0
0001
Card logic error
SD memory card data line or IC6001 (VENUS 4)
0002
Card physical error
SD memory card data line or IC6001 (VENUS 4)
0004
Write error
SD memory card data line or IC6001 (VENUS 4)
39*0
0005
Format error
CPU, 
ASIC hard
Stop
38*0
0001
Camera task finish process time out.
Communication between Lens system and IC6001 (VENUS 4)
0002
Camera task invalid code error.
IC6001 (VENUS 4)
0100
File time out error in recording motion image
IC6001 (VENUS 4)
0200
File data send error in recording motion image
IC6001 (VENUS 4)
0300
Single or burst recording brake time out.
Operation
Power on
3B*0
0000
FLASHROM processing early period of camera during movement.
Zoom
Zoom
3C*0
0000
Inperfect zoom lens processing
Zoom lens
35*0
0000
|
FFFF
Software error
(0-7bit : command, 8-15bit : status)
35*1
0000
Though record preprocessing is necessary, it is not called.
35*2
0000
Though record preprocessing is necessary, it is not completed.
Attribute
Main item
Sub item
Error code
Contents (Upper)
High 4 bits Low 4 bits
Check point (Lower)
Page of 50
Display