WV-CW860, WV-CW864E - Panasonic Video Monitoring Service Manual (repair manual). Page 7

Read Panasonic WV-CW860 / WV-CW864E Service Manual online

– 3 –
2. Disassembling Procedure for the
Adjustment
8
Referring to Fig. 2-1, loosen four screws that secure the
Dome Cover Ass'y and remove the Dome Cover Ass'y.
Fig. 2-1
8
Referring to Fig. 2-2, remove four screws that secure the
Camera Unit and one screw that secures the Earth Lug,
then pull up the Camera Unit.
Fig. 2-2
8
CCD Mounting Adjustment Jig (Part No. : V0MA1120AN)
as shown in Fig. 1-8.
Fig. 1-8
Remove four screws.
Dome Cover Ass'y
Camera Unit
Remove four screws.
Remove one screw.
Earth Lug
UP
A
B
C
UP
A
B
C
D
Page of 53
Display

Click on the first or last page to see other WV-CW860 / WV-CW864E service manuals if exist.