ORDER NO. AVS0702854C0
S16
Heater Unit
WV-CW4H
SPECIFICATIONS
 
M a t s u s h i t a   E l e c t r i c   I n d u s t r i a l   C o . ,   L t d .
A l l   r i g h t s   r e s e r v e d .   U n a u t h o r i z e d   c o p y i n g   a n d
d i s t r i b u t i o n   i s   a   v i o l a t i o n   o f   l a w .
2 0 0 7
The  Product  with  PbF
STANDARD ACCESSORIES
Power source:
Supplied from the camera (24 V AC, 60Hz for NTSC model / 50 Hz for PAL model)
*Camera power supply use 24 V AC, not available with 12 V DC power supply.
Power consumption:
6 W
Ambient temperature:
–30 °C - +50 °C {–22 °F to 122 °F}
Ambient humidity:
90 % or less
Dimensions:
29 mm (H) x 89 mm (W) x 114 mm (D)
[1.14" (H) x 3.50" (W) x 4.49" (D)] (excluding connector)
Weight:
Approx. 40 
g (0.09 lbs)
Fixing screw (M2 x 12) .......................................................................... 1 pc.
Leaflet ................................................................................................... 1 pc.
Warranty for NTSC model  .................................................................... 1 pc.
Leaflet for PAL model............................................................................ 1 pc.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, 
DO NOT REMOVE COVER (OR BACK). NO USER 
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This symbol warns the user that uninsulated voltage within 
the unit may have sufficient magnitude to cause electric 
shock. Therefore, it is dangerous to make any kind of contact 
with any inside part of this unit.
This symbol alerts the user that important literature concerning 
the operation and maintenance of this has been included.
Therefore,  it  should  be  read  carefully  in  order  to avoid 
any problems.
T
here are special components used in this equipment which are important for safety. These parts are indicated 
by the ”
 
Y
 
” mark on the schematic diagram and the replacement parts list. It is essential that these critical 
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
About  Lead  Free  Solder (PbF)
Distribution of PbF PCB:
PCBs (manufactured) using lead free solder (PbF) will have a stamp on the PCB.
Caution:
8
Lead free solder has a higher melting point than standard solder. Typically the melting points is 35 °C – 40 °C
(95 °F – 104 °F) higher. Please use a soldering iron with temperature control and adjust it to 360 °C – 370 °C
(680 °F – 698 °F). In case of using high temperature soldering iron, please be careful not to heat too long.
8
Lead free solder will tend to splash when heated too high (600 °C / 1112 °F).
8
Lead free solder (Sn - 3.0Ag – 0.5Cu) or equivalents are recommended on repairing our lead free soldered PCB.
Y   WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the 
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to 
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any 
attempt to service or repair the product or products dealt with in this service information by anyone else could 
result in serious injury or death.
CONTENTS
INSTALLATION
.......................................................................................................................................................1-1
WIRING DIAGRAM
..................................................................................................................................................2-1
SCHEMATIC DIAGRAM
SENSOR BOARD / HEATER BOARD .................................................................................................................3-1
CONDUCTOR VIEW
SENSOR BOARD / HEATER BOARD .................................................................................................................4-1
EXPLODED VIEW
....................................................................................................................................................5-1
REPLACEMENT PARTS LIST
................................................................................................................................6-1
1-1
INSTALLATION
Heater unit screw
Optional heater 
connector
1. Open the dome cover.
2. Place the heater unit in the camera and fix it with the supplied screw (x1).
3. Insert the harness (x1) into the heater unit connector of the camera.
Note: Attach the desiccant pack so that it does not block ventilation holes or hang over the
top of the wall.
4. Attach the dome cover.
Note: Do not to pinch the harness cable.
5. Connect the heater power cable of the camera.
WIRING DIAGRAM
E10
TO
CAMERA
3
1
E1
1
3
CN2
4
1
CN1
SENSOR
BOARD
HEATER BOARD
2-1
Page of 8
Display

Download Panasonic WV-CW4H Service Manual (Repair Manual)

Here you can read online and download Panasonic WV-CW4H Service Manual in PDF. WV-CW4H service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic WV-CW4H Video Monitoring. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.