WV-CU161C - Panasonic Video Monitoring Service Manual (repair manual). Page 6

Read Panasonic WV-CU161C Service Manual online

– 3 –
Rear View
POWER
OFF
SIGNAL GND
ON
CAMERA
IN
RS485
ALARM
DATA
TERM
VIDEO
OUT
RESET OUT
ALARM IN
RECOVER IN
ALARM OUT
ALARM IN
LINE
COAX
RS485
4
2
ON
OFF
1
2
G
3
4
R
T
A
B
A
B
G
r t y
u
i
o
!0
!1
e
q w
q
Alarm Switch 
This switch is used to specify the functions for the 5-pin
terminal adjacent to the switch. When the switch is set to
the upper position, the terminals supply and accept the
alarm related signals with a Time Lapse VTR. When the
switch is in the lower position, the terminals accept
alarm inputs 1, 2, 3 and 4.
w
Alarm Terminals
Terminal functions are specified by the alarm switch
position as shown in the table.
e
RS-485 Terminal
This terminal is used to exchange control data with the
camera site.
r
Termination Switch (TERM ON/OFF)
This switch is used to terminate the RS-485 communica-
tion lines.
It should normally be kept in the ON position.
t
Line Selection Switch (LINE 4/2)
This switch is used to select full-duplex (4-lines) or half-
duplex (2-lines) for the communication lines.
y
Data Selection Switch (DATA COAX/RS485)
This switch selects the data communication route from
among the multiplexing data on a coaxial cable or when
using an RS-485 line.
u
Video Output Connector (VIDEO OUT)
This connector supplies composite video signals from
the camera.
i
Camera Input Connector (CAMERA IN)
This connector accepts the multiplexed video and con-
trol data signals from the specified camera or a specified
receiver.
o
AC Cord
!0
Power Switch (POWER)
This switch is used to turn the System Controller power
on and off.
Caution: In the following cases, disconnect the AC cord
from the service outlet, or switch off an ALL-POLE
MAIN SWITCH with a contact separation of at least
3 mm in each pole incorporated in the electrical
insulation of the building.
This is to be used when the controller needs to be
isolated from the AC mains, when the controller will
not be used for a long time, and when there is light-
ning.
!1
Signal Ground Terminal (SIGNAL GND)
Pin #
1
2
G
3
4
Switch Position
Up
Alarm Input
Alarm Output
Signal ground
Recover Input
Reset Output
Down
Alarm Input 1
Alarm Input 2
Signal ground
Alarm Input 3
Alarm Input 4