ORDER NO. AVS0305497A8
Colour CCTV Cameras
WV-CLR920A/WV-CLR924AE
Please file and use this service manual together with original service manual for Model No. WV-CL924A/
WV-CL924AE, Order No. AVS0304494C8.
Simplified
WV-
CLR924
CLR924
SPECIFICATIONS
Pick-up Device:
762 (H) x 582 (V) pixels, Interline Transfer CCD
Scanning Area:
6.45 (H) x 4.84 (V) mm (Equivalent to scanning area of 1/2” pick-up tube)
Scanning:
625 lines/50 fields/25 frames
Horizontal:
15.625 kHz
Vertical:
50 Hz
Synchronization:
Internal, Line-locked, External (VS/VBS) or Multiplexed Vertical Drive (VD2) selectable
Video Output:
1.0 V[p-p] PAL composite 75 
/BNC connector
Horizontal Resolution:
480 lines (C/L), 570 lines (B/W)
Signal-to-Noise Ratio:
50 dB (AGC OFF, weight ON)
Minimum Illumination:
0.14 lx (0.014 footcandle) at F1.4 (C/L), 0.01 lx (0.001 footcandle) at F1.4 (B/W)
Gain Control:
AGC ON or OFF selectable (SET UP MENU)
White Balance:
ATW1, ATW2 or AWC selectable (SET UP MENU)
Aperture:
Variable (SET UP MENU)
Electronic Light Control:
Equivalent to continuous variable shutter speeds between 1/50 s and 1/10 000 s
AGC:
ON (DNR-H), ON (DNR-M), ON (DNR-L) or OFF selectable (SET UP MENU)
Backlight Compensation:
Preset ON or OFF selectable (SET UP MENU)
Electronic Shutter Speed:
1/50 (OFF), 1/120, 1/250, 1/500, 1/1 000,1/2 000,1/4 000, 1/10 000 s selectable
Lens Mount:
CS-mount
ALC Lens:
DC or Video selectable (SET UP MENU)
Ambient Operating Temperature:
–10 °C - +50 °C (14 °F - 122 °F)
Ambient Operating Humidity:
Less than 90 %
Power Source and
WV-CLR920A:
220 - 240 V AC 50 Hz  5.5 W
Power Consumption:
WV-CLR924AE: 24 V AC 50 Hz  5.1 W
12 V DC  520 mA
Alarm Out: 
Collector-output
OFF (Open or 4 V DC - 5 V DC)/ON (
1 V 50 mA)
Day/Night In: 
Pulled-up to 5 V DC
OFF (Open)/ON (0 V 0.2 mA)
(Lens: Option)
2 0 0 3
M a t s u s h i t a   E l e c t r i c   I n d u s t r i a l   C o . ,   L t d .
A l l   r i g h t s   r e s e r v e d .   U n a u t h o r i z e d   c o p y i n g   a n d
d i s t r i b u t i o n   i s   a   v i o l a t i o n   o f   l a w .
The  Product  with  PbF
STANDARD ACCESSORIES
Body Cap .................................................................... 1 pc.
ALC Lens Connector (YWM1943A)  ............................ 1 pc.
AC Power Cord (only for WV-CLR920A) ..................... 1 pc.
Floppy Disk ................................................................. 2 pcs.
Instructions for RS485 camera series ......................... 1 pc.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, 
DO NOT REMOVE COVER (OR BACK). NO USER 
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This symbol warns the user that uninsulated voltage within 
the unit may have sufficient magnitude to cause electric 
shock. Therefore, it is dangerous to make any kind of contact 
with any inside part of this unit.
This symbol alerts the user that important literature concerning 
the operation and maintenance of this has been included.
Therefore,  it  should  be  read  carefully  in  order  to avoid 
any problems.
T
here are special components used in this equipment which are important for safety. These parts are indicated 
by the ”
 
Y
 
” mark on the schematic diagram and the replacement parts list. It is essential that these critical 
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
About  Lead  Free  Solder (PbF)
Distribution of PbF PCB:
PCBs (manufactured) using lead free solder (PbF) will have a stamp on the PCB.
Caution:
8
Lead free solder has a higher melting point than standard solder. Typically the melting points is 35 
°
C – 40 
°
C
(95 
°
F – 104 
°
F) higher. Please use a soldering iron with temperature control and adjust it to 360 
°
C – 370 
°
C
(680 
°
F – 698 
°
F). In case of using high temperature soldering iron, please be careful not to heat too long.
8
Lead free solder will tend to splash when heated too high (600 
°
C / 1112 
°
F).
8
Lead free solder (Sn - 3.0Ag – 0.5Cu) or equivalents are recommended on repairing our lead free soldered PCB.
Y
   WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the 
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to 
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any 
attempt to service or repair the product or products dealt with in this service information by anyone else could 
result in serious injury or death.
Dimensions (without lens):
74 mm (W) x 55 mm (H) x 120 mm (D)
[2-15/16” (W) x 2-3/16” (H) x 4-13/16” (D)]
Weights (without lens):
WV-CLR920A:
0.45 kg (1.0 lbs.) (without power cord)
WV-CLR924AE: 0.44 kg (1.0 lbs.)
Weights and dimensions indicated are approximate.
Specifications are subject to change without notice.
CONTENTS
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ..............................................................................1-1
ADJUSTMENT PROCEDURE .................................................................................................................................2-1
WIRING DIAGRAM ..................................................................................................................................................3-1
OVERALL BLOCK DIAGRAM
(2/2) ......................................................................................................................................................................3-2
SCHEMATIC DIAGRAM 
MAIN BOARD (3/3)...............................................................................................................................................4-1
I/F BOARD / TERMINAL BOARD .........................................................................................................................4-2
CONDUCTOR VIEW
I/F BOARD / TERMINAL BOARD  ........................................................................................................................5-1
EXPLODED VIEW
WV-CLR920A .......................................................................................................................................................6-1
WV-CLR924AE .....................................................................................................................................................6-2
REPLACEMENT PARTS LIST ................................................................................................................................7-1
This service manual describes difference from the WV-CL920A/WV-CL924AE.
• As for the rest of information, please refer to the original service manual for WV-CL920A/WV-CL924AE according to the table
below.
Item
WV-CL920A/WV-CL924AE
ADJUSTMENT PROCEDURE
Refer to the page 2-1
LOCATION OF TEST POINTS AND ADJUSTING CONTROLS
Refer to the page 2-11
OVERALL BLOCK BIAGRAM
(1/2)
Refer to the page 3-1
SCHEMATIC DIAGRAM
SENSOR BOARD
Refer to the page 4-1
MAIN BOARD (1/3)
Refer to the page 4-2
MAIN BOARD (2/3)
Refer to the page 4-3
CONDUCTOR VIEW
SENSOR BOARD
Refer to the page 5-1
MAIN BOARD (COMPONENT SIDE)
Refer to the page 5-2
MAIN BOARD (PATTERN SIDE)
Refer to the page 5-3
REPLACEMENT PARTS LIST
SENSOR BOARD
Refer to the page 7-1
1-1
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
<WV-CLR920A>
<WV-CLR924AE>
WV-
CLR920A
FB
LOCK
FB
LOCK
WV-
CLR920A
VIDEO OUT
GEN-LOCK
AC 24V
IN
DC 12V
IN
GND
2
1
r
e
!5
!5
!4
!4
q
w
!0
i
!3
y
t
u
o
!1
!2
!9
!6!7!8
@0
VIDEO OUT
GEN-LOCK
220 - 240V ~  50Hz
IN/OUTPUT
TERMINAL
IN/OUTPUT
TERMINAL
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
Hi-Z-G/L 75
Hi-Z-
4-LINE-2-LINE
RS485
LINE TERM
Slide the panel to the left until it locks.
q
Auto Iris Lens Connector
This connector is used to connect the auto iris lens with a
4-pin male connector supplied as a standard accessory
(Part No. YWM1943A).
w
Flange-back Adjusting Ring (FB)
This ring is used to adjust the back focal length or picture
focus. Rotate this ring upward or downward for a CS-mount
lens. In case of using a C-mount lens, adjust it with the C-
mount adapter.
e
Lens (Option)
r
Focus Fixing Screw (LOCK)
t
Camera Mounting Screw Hole
This hole is used to mount the camera onto a mounting
bracket.
y
Down Button (
)
This button is used to move the cursor downward. It is also
used to select items in the CAM SET UP menu.
u
Right Button (
)
This button is used to move the cursor to the right. It is also
used to select the mode and can be used to adjust some
levels.
i
Left Button (
)
This button is used to move the cursor to the left. It is also
used to select the mode and can be used to adjust some
levels.
o
Up Button (
)
This button is used to move the cursor upward. It is also
used to select items in the CAM SET UP menu.
!0
Set Button (
)
This button is used to activate an item selected in the CAM
SET UP menu.
!1
Gen-lock Termination Switch (Hi-Z, G/L 75
)
Set this switch to Hi-Z when a gen-lock video input signal is
looped through. In all other cases, set this switch to 75 
.
!2
RS-485 Termination Switch (Hi-Z, RS485 LINE TERM)
This switch is used to terminate of the RS485 terminal.
Normally keep it LINE TERM position.
!3
Full duplex/Half duplex Selection Switches 
(4-LINE/2-LINE)
These triple switches are used to select either full duplex
(left side) or half duplex (right side) for the communication
lines.
The selected full or half duplex setting will be enabled after
the camera is powered up again.
!4
Gen-lock Input Connector (GEN-LOCK)
This connector is used to connect an external system for
synchronization.
!5
Video Output Connector (VIDEO OUT)
This connector is used to connect with the VIDEO IN con-
nector of the monitor.
!6
RS485 Terminals
(RS485, T(A)/T(B)/R(A)/R(B)/GND)
These terminals are used for RS-485 Camera site commu-
nication. Connect RS-485 cables to these terminals.
!7
Alarm Output Terminal (ALARM OUT/GND)
Connects to the alarm input connector (terminal) of an
external device. When the camera detects motion, the
alarm output signal is supplied to the connected external
device (Open collector output: 16 V DC, 100 mA max).
Note:
This signal output is not affected by the alarm data
setting in the RS485 setup operations. 
Page of 18
Display

Download Panasonic WV-CLR920A / WV-CLR924AE Service Manual Simplified

Here you can read online and download Panasonic WV-CLR920A / WV-CLR924AE Service Manual Simplified in PDF. WV-CLR920A / WV-CLR924AE service manual simplified will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic WV-CLR920A / WV-CLR924AE Video Monitoring. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.