ORDER NO. AVS0304494C8
Colour CCTV Cameras
WV-CL920A/WV-CL924AE
WV-
CL924A
SPECIFICATIONS
Pick-up Device:
762 (H) x 582 (V) pixels, Interline Transfer CCD
Scanning Area:
6.45 (H) x 4.84 (V) mm (Equivalent to scanning area of 1/2” pick-up tube)
Scanning:
625 lines/50 fields/25 frames
Horizontal:
15.625 kHz
Vertical:
50 Hz
Synchronization:
Internal, Line-locked, External (VS/VBS) or Multiplexed Vertical Drive (VD2) selectable
Video Output:
1.0 V[p-p] PAL composite 75 
/BNC connector
Horizontal Resolution:
480 lines (C/L), 570 lines (B/W)
Signal-to-Noise Ratio:
50 dB (AGC OFF, weight ON)
Minimum Illumination:
0.14 lx (0.014 footcandle) at F1.4 (C/L), 0.01 lx (0.001 footcandle) at F1.4 (B/W)
Gain Control:
AGC ON or OFF selectable (SET UP MENU)
White Balance:
ATW1, ATW2 or AWC selectable (SET UP MENU)
Aperture:
Variable (SET UP MENU)
Electronic Light Control:
Equivalent to continuous variable shutter speeds between 1/50 s and 1/10 000 s
AGC:
ON (DNR-H), ON (DNR-M), ON (DNR-L) or OFF selectable (SET UP MENU)
Backlight Compensation:
Preset ON or OFF selectable (SET UP MENU)
Electronic Shutter Speed:
1/50 (OFF), 1/120, 1/250, 1/500, 1/1 000,1/2 000,1/4 000, 1/10 000 s selectable (SET UP MENU)
Lens Mount:
CS-mount
ALC Lens:
DC or Video selectable (SET UP MENU)
Ambient Operating Temperature:
–10°C - +50°C (14°F - 122°F)
Ambient Operating Humidity:
Less than 90 %
Power Source and
WV-CL920A:
220 - 240 V AC 50 Hz  5.1 W
Power Consumption:
WV-CL924AE: 24 V AC 50 Hz  4.7 W
12 V DC  440 mA
Alarm Out: 
Collector-output
OFF (Open or 4 V DC - 5 V DC)/ON (
1 V 50 mA)
Day/Night In: 
Pulled-up to 5 V DC
OFF (Open)/ON (0 V 0.2 mA)
(Lens: Option)
2 0 0 3
M a t s u s h i t a   E l e c t r i c   I n d u s t r i a l   C o . ,   L t d .
A l l   r i g h t s   r e s e r v e d .   U n a u t h o r i z e d   c o p y i n g   a n d
d i s t r i b u t i o n   i s   a   v i o l a t i o n   o f   l a w .
The  Product  with  PbF
STANDARD ACCESSORIES
Body Cap .................................................................... 1 pc.
ALC Lens Connector (YWM1943A)  ............................ 1 pc.
AC Power Cord (only for WV-CL920A)  ....................... 1 pc.
Dimensions (without lens):
74 mm (W) x 55 mm (H) x 120 mm (D)
[2-15/16” (W) x 2-3/16” (H) x 4-13/16” (D)]
Weights (without lens):
WV-CL920A:
0.45 kg (1.0 lbs.) (without power cord)
WV-CL924AE: 0.44 kg (1.0 lbs.)
Weights and dimensions indicated are approximate.
Specifications are subject to change without notice.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK, 
DO NOT REMOVE COVER (OR BACK). NO USER 
SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This symbol warns the user that uninsulated voltage within 
the unit may have sufficient magnitude to cause electric 
shock. Therefore, it is dangerous to make any kind of contact 
with any inside part of this unit.
This symbol alerts the user that important literature concerning 
the operation and maintenance of this has been included.
Therefore,  it  should  be  read  carefully  in  order  to avoid 
any problems.
T
here are special components used in this equipment which are important for safety. These parts are indicated 
by the ”
 
Y
 
” mark on the schematic diagram and the replacement parts list. It is essential that these critical 
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
About  Lead  Free  Solder (PbF)
Distribution of PbF PCB:
PCBs (manufactured) using lead free solder (PbF) will have a stamp on the PCB.
Caution:
8
Lead free solder has a higher melting point than standard solder. Typically the melting points is 35 
°
C – 40 
°
C
(95 
°
F – 104 
°
F) higher. Please use a soldering iron with temperature control and adjust it to 360 
°
C – 370 
°
C
(680 
°
F – 698 
°
F). In case of using high temperature soldering iron, please be careful not to heat too long.
8
Lead free solder will tend to splash when heated too high (600 
°
C / 1112 
°
F).
8
Lead free solder (Sn - 3.0Ag – 0.5Cu) or equivalents are recommended on repairing our lead free soldered PCB.
Y
   WARNING
This service information is designed for experienced repair technicians only and is not designed for use by the 
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to 
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any 
attempt to service or repair the product or products dealt with in this service information by anyone else could 
result in serious injury or death.
CONTENTS
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ......................................................... 1-1
ADJUSTMENT PROCEDURE ............................................................................................................ 2-1
LOCATION OF TEST POINTS AND ADJUSTING CONTROLS ......................................................2-11 
OVERALL BLOCK DIAGRAM
(1/2) ................................................................................................................................................. 3-1
(2/2) ................................................................................................................................................. 3-2
WIRING DIAGRAM ............................................................................................................................. 3-3
SCHEMATIC DIAGRAM 
SENSOR BOARD ........................................................................................................................... 4-1
MAIN BOARD (1/3) ......................................................................................................................... 4-2
MAIN BOARD (2/3) ......................................................................................................................... 4-3
MAIN BOARD (3/3) ......................................................................................................................... 4-4
I/F BOARD / TERMINAL BOARD ................................................................................................... 4-5
CONDUCTOR VIEW
SENSOR BOARD ........................................................................................................................... 5-1
MAIN BOARD (COMPONENT SIDE) ............................................................................................. 5-2
MAIN BOARD (PATTERN SIDE) .................................................................................................... 5-3
I/F BOARD / TERMINAL BOARD ................................................................................................... 5-4
EXPLODED VIEW 
WV-CL920A .................................................................................................................................... 6-1
WV-CL924AE .................................................................................................................................. 6-2
REPLACEMENT PARTS LIST  .......................................................................................................... 7-1
q
Auto Iris Lens Connector
This connector is used to connect the auto iris lens with a 4-
pin male connector supplied as a standard accessory (Part
No. YWM1943A).
w
Flange-back Adjusting Ring (FB)
This ring is used to adjust the back focal length or picture
focus. Rotate this ring upward or downward for a CS-mount
lens. In case of using a C-mount lens, adjust it with the C-
mount adapter.
e
Lens (Option)
r
Focus Fixing Screw (LOCK)
t
Camera Mounting Screw Hole
This hole is used to mount the camera onto a mounting
bracket.
y
Down Button (
)
This button is used to move the cursor downward. It is also
used to select items in the CAM SET UP menu.
u
Right Button (
)
This button is used to move the cursor to the right. It is also
used to select the mode and can be used to adjust some
levels.
i
Left Button (
)
This button is used to move the cursor to the left. It is also
used to select the mode and can be used to adjust some
levels.
o
Up Button (
)
This button is used to move the cursor upward. It is also
used to select items in the CAM SET UP menu.
!0
Set Button (
)
This button is used to activate an item selected in the CAM
SET UP menu.
1-1
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS
<WV-CL920A>
<WV-CL924AE>
WV-
CL920A
FB
LOCK
FB
LOCK
Hi-Z G/L 75
WV-
CL920A
VIDEO OUT
GEN-LOCK
AC 24V
IN
DC 12V
IN
GND
2
1
r
e
!3
!3
!2
!2
!1
q
w
!0
i
y
t
u
o
!6
!4
!5
!7
VIDEO OUT
GEN-LOCK
GND
220 - 240V ~  50Hz
OUT
ALARM
DAY/
NIGHT
GND
IN
GND
OUT
ALARM
DAY/
NIGHT
GND
IN
Slide the panel to the left until it locks.
!1
Gen-lock Termination Switch (Hi-Z, G/L 75
)
Set this switch to Hi-Z when a gen-lock video input signal is
looped through. In all other cases, set this switch to 75 
.
!2
Gen-lock Input Connector (GEN-LOCK)
This connector is used to connect an external system for
synchronization.
!3
Video Output Connector (VIDEO OUT)
This connector is used to connect with the VIDEO IN con-
nector of the monitor.
!4
Alarm Output Terminal (ALARM OUT, GND)
Connects to the alarm input connector (terminal) of an
external device. When the camera detects motion, the
alarm output signal is supplied to the connected external
device (Open collector output: 16 V DC, 100 mA max).
!5
Day/Night Input Terminal (DAY/NIGHT IN, GND)
This terminal is used for connecting the camera to an exter-
nal day/night detecting sensor.
!6
AC Inlet Socket
Plug the power cord (supplied as a standard accessory)
into this socket and connect it to an AC outlet.
!7
AC/DC Compatible Input Terminal
(DC 12V IN/AC 24V IN, GND)
This terminal is for connecting the 12 V DC or 24 V AC
power supply cord.
Caution:
Connect to 12 V DC (10.8 V-16 V) or 24 V AC
(19.5 V-28 V) class 2 power supply only. Be sure to
connect the grounding lead to the GND terminal when
the power is supplied from a 24 V AC power source.
Page of 34
Display

Download Panasonic WV-CL920A / WV-CL924AE Service Manual (Repair Manual)

Here you can read online and download Panasonic WV-CL920A / WV-CL924AE Service Manual in PDF. WV-CL920A / WV-CL924AE service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic WV-CL920A / WV-CL924AE Video Monitoring. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.