WV-CL270, WV-CL274E - Panasonic Video Monitoring Service Manual Simplified (repair manual). Page 9

Read Panasonic WV-CL270 / WV-CL274E Service Manual Simplified online

– 6 –
(5.1). OB Level Adjustment
Test Point:
CN5 (Video Output Connector)Video Board
8
Connect the terminated Osilloscope with 75
to CN5.
8
Adjust data with the ARROW keys so that the Pedestal
level becomes 50 mV ± 10 mV as shown in Fig. 4-4.
Fig. 4-4
8
Press the ENTER key for next adjustment.
(5.2). Video Output Gain Adjustment
Test Point:
CN5 (Video Output Connector)Video Board
8
Keep the Colour Temperature at 3 200ºK.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the terminated Oscilloscope with 75
to CN5.
8
Adjust data with the ARROW keys so that the Video sig-
nal level becomes 700 mV ± 50 mV as shown in Fig. 4-5.
700 mV 
±
 50 mV
50 mV 
±
 10 mV
Fig.  4-5
8
Press the ENTER key for next adjustment.
(5.3). OB Confirmation (Don't Change Data)
8
Press the ENTER key for next adjustment.
(6.1). Burst Level Adjustment
Test Point:
CN5 (Video Output Connector)Video Board
8
Keep the Colour Temperature at 3 200°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the terminated Oscilloscope with 75 
to CN5.
8
Adjust data with the ARROW keys so that the Burst level
becomes 300 mV ± 10 mV as shown in Fig. 4-6
8
Set the Mode Switch of the Vectorscope to NTSC mode.
8
Adjust data with the ARROW Keys so that the Burst
phase becomes 135° ± 1° as shown in Fig. 4-7.
8
Change the Mode Switch of the Vectorscope from the
NTSC mode to the PAL mode.
8
Adjust data with the ARROW Keys so that the Burst
phase becomes 90° ± 2° as shown in Fig.4-7.
8
Press the ENTER key for next adjustment.
 300 mV 
±
 10 mV
Fig. 4-6
(6.2). Burst Level Adjustment
Test Point:
CN5 (Video Output Connector)Video Board
8
Keep the Colour Temperature at 3 200°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the terminated Oscilloscope with 75 
to CN5.
8
Adjust data with the ARROW keys so that the Burst level
becomes 300 mV ± 10 mV as shown in Fig. 4-6.
8
Set the Mode Switch of the Vectorscope to NTSC mode.
8
Adjust data with the ARROW Keys so that the Burst
phase becomes 135° ± 1° as shown in Fig. 4-7.
8
Change the Mode Switch of the Vectorscope from the
NTSC mode to the PAL mode.
8
Adjust data with the ARROW Keys so that the Burst
phase becomes 90° ± 2° as shown in Fig.4-7.
8
Press the ENTER key for next adjustment.
Page of 27
Display

Click on the first or last page to see other WV-CL270 / WV-CL274E service manuals if exist.