WU-R45E - Panasonic Video Monitoring Service Manual (repair manual). Page 3

Read Panasonic WU-R45E Service Manual online

- 1 -
TERMINAL CONNECTIONS
For EMG24V break control
C
R
R
SPEAKER
N
C
N
To speakers
To speaker output terminals of
extension output control unit
To EMG24V break terminals of 
extension output control unit (no polarity)
To next system (Up to 10 of WU-R45E can be connected.)
NC
NC
0V
MAIN AMP
CONT2
CONT1
EMG24V BREAK 
Local amplifier connection
Connector, local
amplifier side
Connector for local amplifier
Amplifier selection switch between main and local
Main amplifier side: Audio output from the main amplifier sounds
through the speaker.
Local amplifier side: Audio output from the local amplifier sounds
through the speaker under normal conditions. However, the
local amplifier is replaced with the main amplifier by external
control under emergency conditions.
2
4
N
R
C
1
3
2
N
Configuration of 
connector pins
Configuration of 
connector pins
Local amplifier
Local amplifier
1
3
4
C
Two-wire system
Three-wire system
Note:
[ALL CALL] announcement is not available.
Note:
[ALL CALL] announcement is available.
Page of 6