Read Panasonic SC-NT10E / SC-NT10P / SC-NT10PC (serv.man2) Service Manual Supplement online
PSG1311068SE
A6
Wireless Speaker System
Model No.
SC-NT10E
SC-NT10P
SC-NT10PC
SC-NT10P
SC-NT10PC
Product Color: (D)...Orange Type
(A)...Blue Type
Subject : Additional contents on Vacuum Test.
TABLE OF CONTENTS
PAGE
PAGE
1 Vacuum Test ------------------------------------------------------- 2
1.1. Replacement parts for periodic maintenance ------ 2
1.2. Inspection Procedure ------------------------------------- 3
1.2. Inspection Procedure ------------------------------------- 3
Please file and use this supplement manual together with the service manual for
Model No. SC-NT10P/PC/E-A/D Order No. PSG1307003CE
Model No. SC-NT10P/PC/E-A/D Order No. PSG1307003CE
2
1 Vacuum Test
After the replacement of parts, it is required to carry out the vacuum performance.
1.1.
Replacement parts for periodic maintenance
3
1.2.
Inspection Procedure
Please set the condition before the vacuum test.
Setup:
Setup:
• Vacuum Inspector Jig Part No : RFKZ0528
• Air pressure = 3Kpa
• Vacuuming time = 10sec.
• Adjust the Air pressure control dial and make sure the air pressure on the indicator.
• Air pressure = 3Kpa
• Vacuuming time = 10sec.
• Adjust the Air pressure control dial and make sure the air pressure on the indicator.
Step 1 : Before test setup: cover the passive speaker with low adhesive tape to prevent air leakage from the gap.
Tape width is about 60mm and wider than speaker diameter (about 46mm).
Step 2 : Turn over the unit & place it on the table.
Step 3 : Put the vacuum nozzle to the vacuum hole of the unit with fasten. (photo below)
When 15 seconds pass after stopping vacuuming for 10 seconds, the air pressure should be higher than 0.3Kpa.
Tape width is about 60mm and wider than speaker diameter (about 46mm).
Step 2 : Turn over the unit & place it on the table.
Step 3 : Put the vacuum nozzle to the vacuum hole of the unit with fasten. (photo below)
When 15 seconds pass after stopping vacuuming for 10 seconds, the air pressure should be higher than 0.3Kpa.
It is highly recommended to change the following 5 mechanical parts at the same time if any of the part need replacement.
1. TERMINAL LID
2. BUTTON
3. CHASSIS PACKING
4. CABINET ORING
5. WATER PROOF SHEET
2. BUTTON
3. CHASSIS PACKING
4. CABINET ORING
5. WATER PROOF SHEET
Kit supplied Part No : RFKVSCNT10
IPSG1311