I Amplifier Section
RMS output power of each channel driven
10% total harmonic distortion
1 kHz Front CH
70 W per channel (4
Ω)
1 kHz Center CH
70 W per channel (4
Ω)
100 Hz Subwoofer CH
90 W per channel (3
Ω)
Total RMS output power
300 W
Total harmonic distortion
half power at 1kHz (Front CH)
0.5 % (4
Ω )
Input sensitivity
TV, AUX 3
450 mV, IHF’66
S/N at rated power (4
Ω)
BD/DVD, TV, AUX 1, AUX 2
80 dB
Input impedance
TV, AUX 3
47 k
Ω
Tone controls
BASS
50 Hz, +6 dB to -6 dB
TREBLE
20 kHz, +6 dB to -6 dB
Digital input
Optical
2
Coaxial
1
SC-HTR210E
SC-HTR210EB
SC-HTR310E
SC-HTR310EB
Colour
(K)... Black Type
(K)... Black Type
HDMI Input
1
HDMI Output
1
This system supports “HDAVI Control 1” function.
I General
Power supply
AC 230V to 240 V, 50 Hz
Power consumption
Main set
68 W
Standby (HDMI ON)
0.7 W
Standby (HDMI OFF)
0.3 W
I Rack System
(SC-HTR310)
(SC-HTR310)
INCLUDING SPEAKER
Dimensions (W x H x D)
1300 mm x 444 mm x 458 mm
Mass
approx. 50 kg
* Mass is a Completed (AMP, Speaker Unit inc)
Maximum Loading Weight
80 kg
(SC-HTR210)
INCLUDING SPEAKER
Home Theater Audio System
Specification
ORDER NO. MD0804007CE
Dimensions (W x H x D)
1080 mm x 444 mm x 458 mm
Mass
approx. 43 kg
* Mass is a Completed (AMP, Speaker Unit inc)
Maximum Loading Weight
80 kg
I Speaker System
FRONT (L/R)
FRONT (L/R)
1-Way 1 Speaker System
(Bass Refl ect)
6.5 cm Cone Type Full Range x1
1
Safety Precautions
3
2
Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
7
3
Handling the Lead free Solder
8
4
Operating Procedures
9
5
Self Diagnosis Display Function
26
6
HDMI Checking Method
29
7
Assembling and Disassembling
31
8
Service Position
84
9
Voltage Measurement & Waveform Chart
91
CENTER
1-Way 1 Speaker System
(Bass Refl ect)
6.5 cm Cone Type Full Range x1
SUBWOOFER
1-Way 2 Speaker System
(Bass Refl ect)
13 cm Cone Type Woofer x2
Notes :
1. Specifi cations are subject to change without notice.
2. Total harmonic distortion is measured by the digital spectrum
analyser.
analyser.
10 Wiring Connection Diagram
101
11 Block Diagram
103
12 Notes Of Schematic Diagram
107
13 Schematic Diagram
109
14 Printed Circuit Board Diagrams
125
15 Illustration of IC’s, Transistors and Diodes
133
16 Terminal Function of IC’s
134
17 Exploded Views
135
18 Replacement Parts List
143
CONTENTS
Page
Page
2
SC-HTR210E / SC-HTR210EB / SC-HTR310E / SC-HTR310EB
1.1.2. Leakage Current Hot Check
1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, ensure that all the protective devices such as insulation barriers, insulation papers shields are properly installed.
3. After servicing, check for leakage current checks to prevent from being exposed to shock hazards.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Using an ohmmeter measure the resistance value, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
chassis, the reading should be between 1M
Ω and 5.2Ω.
When the exposed metal does not have a return path to the chassis, the reading must be
.
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
Ω, 10 watts resistor, in parallel with a 0.15µF capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. should the measurement is outside of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and re-checked before it is returned
to the customer.
specified, there is a possibility of a shock hazard, and the equipment should be repaired and re-checked before it is returned
to the customer.
Fig. 1
3
SC-HTR210E / SC-HTR210EB / SC-HTR310E / SC-HTR310EB
1.2. Caution for AC Cord
4
SC-HTR210E / SC-HTR210EB / SC-HTR310E / SC-HTR310EB