MAIN UNIT
RADIO
Frequency range:
FM;
87.9 - 107.9 MHz (200kHz steps)
87.5 - 108.0 MHz (100kHz steps)
AM;
520 to 1710 kHz (10kHz steps)
Intermediate Frequency:
FM;
10.7MHz
AM;
450kHz
CD PLAYER
Sampling frequency:
44.1kHz
Decoding:
16 bit linear
Beam source:
Semiconductor laser (wavelength
795nm)
Number of channels:
2 channel, stereo
Wow and flutter:
Less than possible measurement
data
D/A converter:
MASH(1 bit DAC)
Terminals
 2006      
SC-EN25P
SC-EN26P
SC-EN27PC
Colour
(S)............Silver Type
System
SC-EN25P
Main Unit: SA-EN25P
Speakers: SB-EN25P
SC-EN26P
Main Unit: SA-EN26P
Speakers: SB-EN26P
SC-EN27PC
Main Unit: SA-EN27PC
Speakers: SB-EN25P
Input:
MUSIC
PORT;
3.5mm
stereo
(33k
Ω)
Output:
PHONES: 3.5mm stereo (32
Ω)
GENERAL
Power supply:
AC120V, 60Hz
Power consumption:
16W
Dimensions (W×H×D):
241×206×206mm
(9-1/2”×8-1/8”×8-1/8”)
Mass:
3.1kg (6lb. 13oz.) with speakers
1.8kg (3lb. 15oz.) without speakers
SPEAKERS
Full range:
8cm (3-1/8”), 6
Ω×2
Dimensions (W×H×D):
91mm×206mm×176mm
(3-19/32”×8-1/8”×6-15/16”)
Power consumption in standby mode: 2.0W
Note:
CD Stereo System
Specifications
ORDER NO.AD0603021CE
A6
Specifications are subject to change without notice.
Mass and dimensions are approximate.
MPEG Layer-3 audio decording technology
licenced from Fraunhofer IIS and Thomson multimedia.
 1 Accessories 
3
 2 Location of Control 
3
 3 Safety Precaution 
4
 4 Protection Circuitry 
5
 5 Handling Precautions For Traverse Deck (Optical Pickup)  5
 6 Precaution of Laser Diode 
6
 7 Prevention of Electro Static Discharge (ESD) To
Electrostatically (ES) Devices 
7
 8 Handling the Lead-free Solder 
7
 8.1. 
About lead free solder (PbF) 
7
 9 Operation Checks and Component Replacement 
8
 9.1. 
Main Unit 
8
 9.2. 
Speaker 
15
 10 Self Diagnostic Function 
17
 10.1. Setting of self diagnostic Function 
17
 11 Description of Error Code 
18
 11.1. Error detection for CD Mechanism block 
18
 12 Schematic Diagram 
19
 12.1. Schematic Diagram Notes 
19
 12.2. Schematic Diagram 
21
 12.3. Voltage Value 
25
 13 Printed Circuit Board 
27
 14 Block Diagram 
31
 15 Wiring Connection Diagram 
35
 16 Measurements and Adjustments 
37
 16.1. Tuner Adjustment 
37
 16.2. Adjustment Point 
38
 17 Terminal Functions of ICs 
39
 18 Replacement Parts List 
40
 18.1. SA-EN25P,SA-EN26P and SA-EN27PC 
40
 18.2. SB-EN25P 
45
 18.3. SB-EN26P 
45
 19 Cabinet Parts Location 
46
 19.1. Main Unit 
46
 19.2. Speaker(SB-EN25) 
48
 19.3. Speaker(SB-EN26) 
49
 20 Packaging 
50
CONTENTS
 Page 
Page
2
SC-EN25P / SC-EN26P / SC-EN27PC
1 Accessories
     ·    Remote control........................................................1pc.
(N2QAGB000037): SC-EN25/26
(N2QAGB000038): SC-EN27
     ·    AC power supply cord (RJA0065-1D).......................1pc.
     ·    
Batteries.........................................................................2pc
s.
     ·    FM/AM loop antenna (N1DADYY00003)...................1pc.
Note:
     ·    The included AC power supply cord is for use with this unit
only. Do not use it with other equipment.
2 Location of Control
3
SC-EN25P / SC-EN26P / SC-EN27PC
3 Safety Precaution
(This “Safety Precaution” is applied only in U.S.A.)
 1. Before servicing, unplug the power cord to prevent an electric shock.
 2. When replacing parts, use only manufacturer’s recommended components for safety.
 3. Check the condition of the power cord. Replace if wear or damage is evident.
 4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
 5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance test to prevent the
customer from being exposed to a shock hazard.
Insulation Resistance Test
 1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
 2. Turn on the power switch.
 3. Measure the resistance value with ohmmeter between the jumper AC plug and each exposed metal cabinet part, such as screw
heads, control shafts, handle brackets, etc. Equipment with antenna terminals should read between 3M
Ω and 5.2MΩ to
allexposedparts. (Fig.A) Equipment without antenna terminals should read approximately infinity to all exposed parts. (Fig.B)
*Note: Some exposed partsmay beisolated from the chassis by design. These will read infinity.
(Fig.A)
(Fig.B)
 4. If the measurement is outside the specified limits, there is a possibility of a shock hazard. The equipment should be repaired
and rechecked before it is returned to the customer.
4
SC-EN25P / SC-EN26P / SC-EN27PC
Page of 50
Display

Download Panasonic SC-EN25P / SC-EN26P / SC-EN27PC Service Manual (Repair Manual)

Here you can read online and download Panasonic SC-EN25P / SC-EN26P / SC-EN27PC Service Manual in PDF. SC-EN25P / SC-EN26P / SC-EN27PC service manual will guide through the process and help you recover, restore, fix, disassemble and repair Panasonic SC-EN25P / SC-EN26P / SC-EN27PC Audio. Information contained in service manuals typically includes schematics / circuit diagrams, wiring diagrams, block diagrams, printed wiring boards, exploded views, parts list, disassembly / assembly, pcb.