MAIN UNIT
RADIO
Frequency range:
FM;
87.9 - 107.9 MHz (200kHz steps)
87.5 - 108.0 MHz (100kHz steps)
87.5 - 108.0 MHz (100kHz steps)
AM;
520 to 1710 kHz (10kHz steps)
Intermediate Frequency:
FM;
10.7MHz
AM;
450kHz
CD PLAYER
Sampling frequency:
44.1kHz
Decoding:
16 bit linear
Beam source:
Semiconductor laser (wavelength
795nm)
Number of channels:
2 channel, stereo
Wow and flutter:
Less than possible measurement
data
D/A converter:
MASH(1 bit DAC)
Terminals
2006
SC-EN25P
SC-EN26P
SC-EN27PC
SC-EN26P
SC-EN27PC
Colour
(S)............Silver Type
(S)............Silver Type
System
SC-EN25P
Main Unit: SA-EN25P
Speakers: SB-EN25P
SC-EN26P
Main Unit: SA-EN26P
Speakers: SB-EN26P
SC-EN27PC
Main Unit: SA-EN27PC
Speakers: SB-EN25P
SC-EN25P
Main Unit: SA-EN25P
Speakers: SB-EN25P
SC-EN26P
Main Unit: SA-EN26P
Speakers: SB-EN26P
SC-EN27PC
Main Unit: SA-EN27PC
Speakers: SB-EN25P
Input:
MUSIC
PORT;
3.5mm
stereo
(33k
Ω)
Output:
PHONES: 3.5mm stereo (32
Ω)
GENERAL
Power supply:
AC120V, 60Hz
Power consumption:
16W
Dimensions (W×H×D):
241×206×206mm
(9-1/2”×8-1/8”×8-1/8”)
Mass:
3.1kg (6lb. 13oz.) with speakers
1.8kg (3lb. 15oz.) without speakers
SPEAKERS
Full range:
8cm (3-1/8”), 6
Ω×2
Dimensions (W×H×D):
91mm×206mm×176mm
(3-19/32”×8-1/8”×6-15/16”)
(3-19/32”×8-1/8”×6-15/16”)
Power consumption in standby mode: 2.0W
Note:
CD Stereo System
Specifications
ORDER NO.AD0603021CE
A6
Specifications are subject to change without notice.
Mass and dimensions are approximate.
Mass and dimensions are approximate.
MPEG Layer-3 audio decording technology
licenced from Fraunhofer IIS and Thomson multimedia.
1 Accessories
3
2 Location of Control
3
3 Safety Precaution
4
4 Protection Circuitry
5
5 Handling Precautions For Traverse Deck (Optical Pickup) 5
6 Precaution of Laser Diode
6
7 Prevention of Electro Static Discharge (ESD) To
Electrostatically (ES) Devices
7
8 Handling the Lead-free Solder
7
8.1.
About lead free solder (PbF)
7
9 Operation Checks and Component Replacement
8
9.1.
Main Unit
8
9.2.
Speaker
15
10 Self Diagnostic Function
17
10.1. Setting of self diagnostic Function
17
11 Description of Error Code
18
11.1. Error detection for CD Mechanism block
18
12 Schematic Diagram
19
12.1. Schematic Diagram Notes
19
12.2. Schematic Diagram
21
12.3. Voltage Value
25
13 Printed Circuit Board
27
14 Block Diagram
31
15 Wiring Connection Diagram
35
16 Measurements and Adjustments
37
16.1. Tuner Adjustment
37
16.2. Adjustment Point
38
17 Terminal Functions of ICs
39
18 Replacement Parts List
40
18.1. SA-EN25P,SA-EN26P and SA-EN27PC
40
18.2. SB-EN25P
45
18.3. SB-EN26P
45
19 Cabinet Parts Location
46
19.1. Main Unit
46
19.2. Speaker(SB-EN25)
48
19.3. Speaker(SB-EN26)
49
20 Packaging
50
CONTENTS
Page
Page
2
SC-EN25P / SC-EN26P / SC-EN27PC
1 Accessories
· Remote control........................................................1pc.
(N2QAGB000037): SC-EN25/26
(N2QAGB000038): SC-EN27
(N2QAGB000038): SC-EN27
· AC power supply cord (RJA0065-1D).......................1pc.
·
·
Batteries.........................................................................2pc
s.
s.
· FM/AM loop antenna (N1DADYY00003)...................1pc.
Note:
· The included AC power supply cord is for use with this unit
Note:
· The included AC power supply cord is for use with this unit
only. Do not use it with other equipment.
2 Location of Control
3
SC-EN25P / SC-EN26P / SC-EN27PC
3 Safety Precaution
(This “Safety Precaution” is applied only in U.S.A.)
1. Before servicing, unplug the power cord to prevent an electric shock.
2. When replacing parts, use only manufacturer’s recommended components for safety.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance test to prevent the
1. Before servicing, unplug the power cord to prevent an electric shock.
2. When replacing parts, use only manufacturer’s recommended components for safety.
3. Check the condition of the power cord. Replace if wear or damage is evident.
4. After servicing, be sure to restore the lead dress, insulation barriers, insulation papers, shields, etc.
5. Before returning the serviced equipment to the customer, be sure to make the following insulation resistance test to prevent the
customer from being exposed to a shock hazard.
Insulation Resistance Test
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with ohmmeter between the jumper AC plug and each exposed metal cabinet part, such as screw
1. Unplug the power cord and short the two prongs of the plug with a jumper wire.
2. Turn on the power switch.
3. Measure the resistance value with ohmmeter between the jumper AC plug and each exposed metal cabinet part, such as screw
heads, control shafts, handle brackets, etc. Equipment with antenna terminals should read between 3M
Ω and 5.2MΩ to
allexposedparts. (Fig.A) Equipment without antenna terminals should read approximately infinity to all exposed parts. (Fig.B)
*Note: Some exposed partsmay beisolated from the chassis by design. These will read infinity.
*Note: Some exposed partsmay beisolated from the chassis by design. These will read infinity.
(Fig.A)
(Fig.B)
4. If the measurement is outside the specified limits, there is a possibility of a shock hazard. The equipment should be repaired
and rechecked before it is returned to the customer.
4
SC-EN25P / SC-EN26P / SC-EN27PC