SA-PM54E, SA-PM54EG - Panasonic Audio Service Manual (repair manual). Page 14

Read Panasonic SA-PM54E / SA-PM54EG Service Manual online

Item
FL Display
Key Operation
Mode Name
Description
Front Key
Volume Setting To Forced Volume
Setting.
     ·    BASS TREBLE set to
0dB.
     ·    H.BASS is off.
 1. 
 2. 
 3. 
In doctor mode:
 1. 
Press [7] button on remote control.
 2. 
Press [8] button on remote control.
 3. 
Press [9] button on remote control.
To exit, press [ENTER] button on remote
control or
button on main unit or
remote control.
TPS
To check FF TPS for
deck.
(For more information,
refer to section 8.1.6)
In doctor mode:
 1. 
Press [
] button on remote
control.
To exit, press [ENTER] button on remote
control or
button on main unit or
remote control.
CD Tray and
Tape Door Open
To check CD Tray and
Tape Door Open.
     ·    BASS TREBLE set to
0dB.
     ·    H.BASS is off.
     ·    CD tray and Cassette
cover shall open
simultaneously.
In doctor mode:
 1. 
Press [1] button on remote control.
To exit, press [ENTER] button on remote
control or
button on main unit or
remote control.
Changer
Operation
To check the CD
Changer Operation.
(For more information,
refer to section 8.1.7)
1. Tray 1 load, tray 2
open then close.
2. Tray 1 load, tray 3
open then close.
3. Tray 1 load, tray 4
open then close.
4. Tray 1 load, tray 5
open then close.
5. CD check mode and
then close.
6. Tray 1 load.
7. After the above
process, [CHNGR_OK]
shall be displayed. If
there is no problems.
Error codes will display if
errors occurs.
In doctor mode:
 1. 
Press [DISC] button on remote control.
To exit, press [ENTER] button on remote
control or
button on main unit or
remote control.
8.1.1. Cassette Mechanism Self-Diagnostic Mode
Below is information on the checking of cassette deck mechanism
No.
Operation Procedures
Micon operation & processing
1
C-mecha Abnormal Detection shall be
executed for DECK 1 only.
Check that all DECK mechanism leaf SW is in OFF state.
2
[
] key is pressed, after loading in a
NORMAL type cassette with the recording tab
on the left side removed.
FF shall be executed for 2 sec, after which STOP.
Check the following.
{ F.REC INH SW } is OFF
{ R.REC INH SW } is ON
{ HALF SW } is ON
Reel pulse toggles between H & L.
3
[
] key is pressed, after loading a
NORMAL, CrO2, METAL type cassette with
the recording tab on the right side removed.
REW shall be executed for 2 sec, after which STOP.
Check the following.
{ F.REC INH SW } is ON
{ R.REC INH SW } is OFF
{ HALF SW } is ON
Reel pulse toggles between H & L.
14
SA-PM54E / SA-PM54EG
Page of 115
Display