SA-PM24EB, SA-PM24EG, SA-PM24EP, SC-PM24EP - Panasonic Audio Service Manual (repair manual). Page 18

Read Panasonic SA-PM24EB / SA-PM24EG / SA-PM24EP / SC-PM24EP Service Manual online

18
6.3.2.
Doctor Mode Table 2
Item
FL Display
Key Operation
Mode Name
Description
Front Key
FL Display Test
To check the FL segments 
display (All segments will 
light up)
In Doctor Mode:
1. Press [DIMMER] button on 
remote control.
To cancel, press [0] button on remote 
control.
To exit Doctor Mode, press 
 but-
ton on main unit or remote control.
Volume Setting
To check for volume setting 
during this mode, Bass & 
treble is set to 0dB & EQ is 
switch off.
In Doctor Mode:
1. Press [7] button on remote control.
To exit Doctor Mode, press 
 but-
ton on main unit or remote control.
In Doctor Mode:
2. Press [8] button on remote control.
To exit Doctor Mode, press 
 but-
ton on main unit or remote control.
In Doctor Mode:
3. Press [9] button on remote control.
To exit Doctor Mode, press 
 but-
ton on main unit or remote control.
CD Loading Test 
(DLS6C)
To determine the reliability of 
CD Loading unit.
To check for the Open/Close 
operation for the CD loading 
unit. It fails when there is 
abnormality in opening or 
closing.
In Doctor Mode:
1. Press [
], [1], [1] button on 
remote control.
To cancel, press [0] button on remote 
control.
To exit Doctor Mode, press 
 but-
ton on main unit or remote control.
(Refer to section 6.3.3 for more infor-
mation)
CD Traverse Test 
(DLS6C)
To check for the traverse unit 
operation. In this mode, the 
first & last track is access & 
read. (TOC). It fails when 
TOC is not completed by IOS 
or the traverse is out of 
focus.
In Doctor Mode:
1. Press [
], [1], [2] button on 
remote control.
To cancel, press [0] button on remote 
control.
To exit Doctor Mode, press 
 but-
ton on main unit or remote control.
(Refer to section 6.3.4 for more infor-
mation)
CD Combination Test 
(DLS6C)
A combination of CD loading 
& traverse unit test.
In Doctor Mode:
1. Press [
], [1], [3] button on 
remote control.
To cancel, press [0] button on remote 
control.
To exit Doctor Mode, press 
 but-
ton on main unit or remote control.
(Refer to section 6.3.5 for more infor-
mation)
Cold Start
To activate cold start upon 
next AC power up. It will set 
to factory shipment condi-
tion.
In Doctor Mode:
1. Press [SLEEP] button on remote 
control.
To exit Doctor Mode, press 
 but-
ton on main unit or remote control.
Page of 99