SA-NS55DBEB - Panasonic Audio Service Manual (repair manual). Page 6

Read Panasonic SA-NS55DBEB Service Manual online

1.3. Before Repair and Adjustment
Disconnect AC power, discharge Power Supply Capacitors C321, C322, C323, C324, C325, C507, C520 and C611 through a 10
Ω,
1W resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
     ·    Current consumption at AC 230 - 240 V, 50 Hz in NO SIGNAL mode should be ~300 mA.
1.4. Protection Circuitry
The protection circuitry may have operated if either of the following conditions are noticed:
     ·    No sound is heard when the power is turned on.
     ·    Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
"shorted", or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
 1. Turn off the power.
 2. Determine the cause of the problem and correct it.
 3. Turn on the power once again after one minute.
Note:
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
1.5. Safety Part Information
Safety Parts List:
There are special components used in this equipment which are important for safety.These parts are marked by
in the
Schematic Diagrams & Replacement Parts List. It is essential that these critical parts should be replaced with manufacturer’s
specified parts to prevent shock, fire or other hazards. Do not modify the original design without permission of manufacturer.
Table 1
Reference No.
Part No.
Part Name & Description
Remarks
L270
G0AR76Y00003
CHOKE COIL
[M]
L271
G0AR76Y00003
CHOKE COIL
[M]
L470
G0AR76Y00003
CHOKE COIL
[M]
L471
G0AR76Y00003
CHOKE COIL
[M]
T501
G4CYAYY00155
TRANSFORMER
[M]
T502
G4CYAYY00137
SUB TRANSFORMER
[M]
RL501
K6B1AEA00015
POWER RELAY
[M]
F1
K5D631BLA012
FUSE
[M]
JK500
K2AA2B000015
JK AC INLET
[M]
A2
K2CT3CA00004
AC CORD
[M]
L500
G0B371HA0005
LINE FILTER
[M]
Z500
ERZV10V511CS
ZENER
[M]
FP502
K5G202A00044
FUSE PROTECTOR
[M]
FP600
K5G502A00039
FUSE PROTECTOR
[M]
301
RAE0165Z-V
TRAVERSE UNIT (W/O CD SERVO
P.C.B.)
[M]
6
SA-NS55DBEB
Page of 97
Display