Read Panasonic SA-MAX700GSK Service Manual online
24
8.4.
Self-Diagnostic Mode
8.5.
Self-Diagnostic Error Code Table
Self-Diagnostic Function (Refer Section 8.4. Self-Diagnostic Mode) provides information on any problems occurring for the unit and
its respective components by displaying the error codes. These error code such as U**, H** and F** are stored in memory and held
unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
its respective components by displaying the error codes. These error code such as U**, H** and F** are stored in memory and held
unless it is cleared.
The error code is automatically display after entering into self-diagnostic mode.
8.5.1.
Power Supply Error Code Table
FL Display
Key Operation
Front Key
Item
Description
Mode Name
To enter into self diagnostic checking
System will perform a check on any
unusual/error code from the memory
unusual/error code from the memory
To clear the stored in memory
(EEPROM IC)
(EEPROM IC)
Self Diagnostic
Mode
Mode
Error code
information
information
Delete error
code
code
Step 1: Select CD mode
(Ensure no disc is inserted).
(Ensure no disc is inserted).
Step 2: Press & hold [ ] button
follow by [
follow by [
] on
main unit for 2 seconds.
Step 1: In self diagnostic mode,
Press [ ] on main unit.
Press [ ] on main unit.
To exit, press [
^
/I] on main
unit or remote control.
Step 1: In self diagnostic mode,
Press [0] on remote control.
Press [0] on remote control.
To exit, press [
^
/I] on main
unit or remote control.
Example:
/
Cold Start
To active cold start upon next AC
power up when reset start is
execute the next time.
power up when reset start is
execute the next time.
In
self diagnostic mode
:
1. Press [3] button on
the remote control.