SA-AKX200PN, SA-AKX200PS, SA-AKX400PN, SA-AKX400PS - Panasonic Audio Service Manual (repair manual). Page 10

Read Panasonic SA-AKX200PN / SA-AKX200PS / SA-AKX400PN / SA-AKX400PS Service Manual online

10
ble cable, cut off the antistatic FFC.
Figure 2-2
2.5.
Grounding for electrostatic breakdown prevention
• As for parts that use optical pick-up (laser diode), the optical pick-up is destroyed by the static electricity of the working environ-
ment. 
Repair in the working environment that is grounded.
2.5.1.
Worktable grounding
• Put a conductive material (sheet) or iron sheet on the area where the optical pickup is placed and ground the sheet.
2.5.2.
Human body grounding
• Use the anti-static wrist strap to discharge the static electricity form your body (Figure 2-3).
Figure 2-3
Page of 72