RX-D55EG - Panasonic Audio Service Manual (repair manual). Page 14

Read Panasonic RX-D55EG Service Manual online

14
6 Self Diagnostic and Doctor Mode Setting
This unit is equiped with features of self diagnostic & doctor mode setting for checking the functions & reliability.
6.1.
Self Diagnostic Mode
6.1.1.
Self Diagnostic Table
6.1.2.
Self Diagnostic Error Code 1 (For CD)
6.1.3.
Self Diagnostic Error Code 2 (For Power Supply)
Self Diagnostic Mode
To enter into self diagnostic 
checking
1. Select CD mode
    (Ensure no CD inserted).
2. Press and hold [    ] for 
    2 seconds follow by [      /+] on
    main unit.
   To exit, press [TAPE/OFF] on 
   main uint.
Item
FL display
Key operation
Mode name
Description
㪁㩷㪁㩷㪁㩷䋺㩷㪜㫉㫉㫆㫉㩷㪺㫆㪻㪼
Error code information
Error code will display
Example:
System will perform a check on
any unusual/error code from the 
memory
1. In self diagnosis mode.
2. Press [STOP] for on main unit.
   To exit, press [TAPE/OFF] on 
   main uint.
FL display
Remarks
Error Code
H15
CD Open SW 
Abnormal
During normal operation CD OPEN 
SW On fail to be detected with 4 
sec. Error No. shall be clear by 
force or during cold start.
Diagnostic Contents
Description of error
F15
CD REST SW 
Abnormal
CD traverse position intial setting 
operation failsafe counter (1000 
ms) waiting  for REST SW to turn 
on.  Error No. shall be clear by 
force or during cold start.
F26
Communication 
between CD servo 
LSI and micro-p 
abnormal.
CD function DTMS command, after 
system setting, If SENSE = 'L' 
cannot be detected. Memory shall 
contain F26 code. After Power on, 
CD function shall continue, error 
display shall be "NO DISC".
Error No. shall be clear by force or 
cold start.
For CD Mechanism Unit 
(DLS6F) (For Traverse).
Press [    ] on main unit 
for next error
For CD Mechanism Unit 
(DLS6F) (For Traverse).
Press [    ] on main unit 
for next error
For CD Mechanism Unit 
(DLS6F) (For Traverse).
Press [    ] on main unit 
for next error
FL display
Remarks
Error Code
U01
Battery Low
Detect the Battery when Battery is 
Low.
Diagnostic Contents
Description of error
F76
Abnormality in the 
output voltage of 
stabilized power 
supply
In normal operation when DCDET1 
is detected "L" (Low) for two 
consecutive times, F76 is 
displayed on FL for 1 second and 
after that PCONT will be turned to 
"L" (Low). This is due to any of the 
DC voltages (+9V, +7V, -7V, +5V, 
+5.3V etc.) not available.
For Power.
Press [    ] on main unit 
for next error
For Power.
Press [    ] on main unit 
for next error
Page of 99
Display

Click on the first or last page to see other RX-D55EG service manuals if exist.