Caution:
Pressing the [VOL+] for 10 seconds is invalid when the password is reset (because no need to delete the password).
4.3.1.3. Authentication Key Deletion Function
Purpose : To delete the authentication key stored in IC recorder.
Procedures:
 1. Enter into test mode (All segment of LCD lights up).
 2. Press and hold [Vol-] for 10 seconds.
 3. Taking off the battery after deleting the authentication key, we can get out of this mode.
(The display only when the authentication key is deleted is as shown in the figure below.)
Caution:
Pressing the [VOL-] for 10 seconds is invalid when the authentication key is reset (in the case of initial value “0xFFFF”).
4.3.1.4. Complete Process Test Mode
Purpose : To check the unit for record, playback, LCD display, USB connection & charging function of the unit.
Caution :
When this checking operation is performed, all recorded data will be cleared.
Note :
For this checking operation, you need the items as follows;
 • Rechargable battery (included)
 • Stereo microphone (included)
 • USB cable (included)
 • Personal computer
Procedures:
 1. Press the [REC/PAUSE], [STOP] and [ERASE] in order.
The below diagram shows on LCD display after each key operation.